Indication/sound
Yellow LED on
Green LED flashes 1.5s/ 2 beeps
Base Unit action
Corresponding switch on.
Individual (All) Switch Off (number 0 is all Off):
Key entry
Press
Press switch number (“
0
” or “
1
”to“
8
”)
Indication/sound
Yellow LED on
Green LED flashes 1.5s/ 2 beeps
Base Unit action
Corresponding switch(s) off.
Switch Scene Control:
Key entry
Press
Press
Press scene number (“
1
”to“
8
”)
Indication/sound
Yellow LED on
Green LED flashes 1.5s/ 2 beeps
Base Unit action
Corresponding switches on/off.
Operation Scene Control:
Key entry
“
Master PSW
”
Press
Press scene number (“
1
”to“
8
”)
Indication/sound
Green LED on
Yellow LED on
Green LED flashes 1.5s/ 2 beeps
Base Unit action
Main and 91-99 zones enter preset state.
How to reset the
i4H-
KP-3S password
1. Take out the battery
2.
Loosen the screws of the plastic case; change the jumper JP7 on the PCB to “CLR”
side.
3.
Insert the battery, and then you would hear 4 beeps which means the password is
reset.
4.
Restore the JP7 to original position, and then tighten the screws.
SPECIFICATIONS
Power: two AAA alkaline batteries.
Supervision: Sends heartbeat signal at 60-minute intervals. When Tamper or
Low -Battery condition is detected, it reports automatically.
Passwords: 9 users, 4 digits for each.
Current Drain: 10uA @standby, 30mA @ RF operation
Estimated battery life: 2 years (@ operate 20 times/day)
Radio: 2-way communication.
Bracket slant angle: 7 degrees.
Size: 65 x 28 x 15 mm (Not including the bracket)
Weight (w/o battery): about 120g