62
—
AP-
16
00T-
PMCL
Item
Setting range
Default value
Description
SequencerFrame
Number
1 to 255
1
Set the number of frames to display
for the selected SequencerIndex.
(Enabled only for TriggerSequencer.)
SequencerSetNext
1 to 128
–
Set the next index to be displayed
for the selected SequencerIndex.
(Enabled only for TriggerSequencer.)
SequencerWidth
SequencerBinning
Horizontal 1: 96 to
1456
SequencerBinning
Horizontal 2: 48 to
728
1456
Set the width of the selected
SequencerIndex.
SequencerHeight
SequencerBinning
Vertical 1: 2 to 1088
SequencerBinning
Vertical 2: 2 to 544
1088
Set the height of the selected
SequencerIndex.
SequencerOffsetX
SequencerBinning
Horizontal 1: 0 to
1440 step 16
SequencerBinning
Horizontal 2: 0 to
744 step 8
0
Set the horizontal offset value for
the selected SequencerIndex.
SequencerOffsetY
SequencerBinning
Vertical 1: 0 to 1086
step 2
SequencerBinning
Vertical 2: 0 to 542
step 2
0
Set the vertical offset value for the
selected SequencerIndex.
SequencerGain
AnalogAll
1.0 to 8.0
1.0
Set the GainAnalogAll value.
SequencerGain
AnalogRed
0.47 to 4.0 / 1.0 to
64.0
1.0
SequencerGain
AnalogGreen
1.0 fixed / 1.0 to 64.0
1.0
SequencerGain
AnalogBlue
0.47 to 4.0 / 1.0 to
64.0
1.0
SequencerExposure
TimeCommon(µs)
Set the exposure time for the
selected SequencerIndex.
SequencerExposure
TimeRed(µs)
SequencerExposure
TimeGreen(µs)
SequencerExposure
TimeBlue(µs)
SequencerLUTEnable
True, False
SequencerBlackLevel
DigitalAll
-133 to 255
0
Set the black level value for the
selected SequencerIndex.
SequencerBinning
Horizontal
1, 2
1
For the selected SequencerIndex,
set the number of pixels in the
horizontal direction for which to
perform binning.
SequencerBinning
Vertical
1, 2
1
For the selected SequencerIndex,
set the number of pixels in the
vertical direction for which to
perform binning.
SequencerLUTMode
Gamma,
LUT
Gamma
Set the sequence LUT mode.
SequencerSetActive
–
–
Displays the active LUT number.
SequencerCommand
Index
–
1
Set this to change the
SequencerIndex. (Enabled only for
CommandSequencer.)
SequencerSetStart
–
1
Specify the first index number to
switch to when starting
[TriggerSequencerMode].