23
8-5 Position Data Table Contents
8-5-1 Position Data Table Contents for PCON, ACON and SCON
The setting items of the position data table are No., Position, Vel, Acc/Dcl, Push, LoTh, Range,
Zone+, Zone-, AccDcl Mode, Cmnd Mode and Stop Mode. They are displayed in 6 screens.
The items of Zone+, Zone-, AccDcl Mode and Stop Mode are enabled (ON) or disabled (OFF)
according to the controller type.
List of ON/OFF of Position Table According to Model
AccDcl Mode
Stop Mode
Position Table
Zone +/-
Trapezoid
S-shape
First-order
Delay
Full Servo
Auto
Servo
OFF
PCON-C/CG/CF
○
PIO pattern: 0, 1, 2, 4, 5
○
× ×
○
○
-CY
○
PIO
pattern:
1
○
× ×
○
○
-SE
○
-
○
× ×
○
×
ACON-C/CG
○
PIO pattern: 0, 1, 2, 4, 5
○
○
○
○
-CY
○
PIO
pattern:
1
○
○
○
○
-SE
○
-
○
○
○
×
SCON positioner
○
PIO pattern: 0, 1, 2, 4, 5
○
○
○
○
(1) No.
Indicates the position data number.
Warning:
Always specify absolute coordinates for the 3-point type of PCON-C/CG, ACON-C/CG
and SCON-C and the proximity switch type of PCON-CY and ACON-CY.
If you specify relative coordinates, a position data error will occur.
In the above case, if you specify “Push,” push completion cannot be judged.
(2) Position: Input the target position to move the actuator to, in [mm].
- Absolute Coordinates:
Input the target location by determining the distance
between the original point and target position. No negative
value can be input.
- Relative Coordinates:
Input the target location by determining the distance
between the current position and target position. Any
negative value can be input (if coordinates are in the
negative direction).
Summary of Contents for CON-T
Page 1: ...Teaching Pendant Operating Manual First edition IAI America Inc ...
Page 2: ......
Page 4: ......
Page 6: ......
Page 14: ...6 6 2 External View External Dimensions ...
Page 78: ...70 Examples of PCON CY Controller On following page ...
Page 79: ...71 From previous page On following page ...
Page 80: ...72 From previous page On following page ...
Page 81: ...73 From previous page ...
Page 95: ......