45
4) Jog Teach
(Method: Tagging the actuator, matching to the desired position and teaching that position into the position
table)
However, only the maximum speed will be gained if the maximum speed is slower than the specified speed.
When jog operation is performed first after power-on, it is required to perform home return operation in
advance. (Refer to page 32.) (Increment specification)
Caution:
Operating instructions are described on the screens of PCON, ACON and SCON.
Example:
2 point continuous loop Point A --> Point B, speed 300mm/sec
Operation
Screen
Reference
1. Press the
key.
2. Press the
key to select
“Teach/Play.”
3. Press the
key to select
“Jog.”
4.
Input the desired jog speed with
the ten keys and press the Return
key.
The input range is from 1 mm/sec
to the safety speed set for the
parameter.
5. Move the slider with the
or
key and match to the
desired position.
6. Press the
key.
Summary of Contents for CON-T