75
8-9 User
Adjustment
8-9-1 Homing Operation and Axis Number Setting
Execute homing.
Set the axis number of the controller (PCON, ACON, RCP-RSI, RCP-RM1, etc.).
Press the
key.
Caution:
Caution: Do not input any numeric value other than 1, 2, 3, 4 and 5119 into Adjust No.
In the case of the RCP or RCP2 controller, 0 or 2 is set to parameter No. 25 (PIO pattern)
(when there is no servo ON input), do not input 92 into Adjust No., either. The controller will be
inoperable due to no servo ON input.
- If you input 1 into Adjust No. and press the Return
key, homing will be performed.
- Axis number setting
Move the cursor to Adjust No. with the key. Input
the axis number and press the Return key.
Input 2 into Adjust No. and press the Return key.
* In the case of the PCON-C/CG and other controllers
for which the axis number is set with the rotary switch
on the front panel of the controller, axis number
setting is not available.
Summary of Contents for CON-T
Page 1: ...Teaching Pendant Operating Manual First edition IAI America Inc ...
Page 2: ......
Page 4: ......
Page 6: ......
Page 14: ...6 6 2 External View External Dimensions ...
Page 78: ...70 Examples of PCON CY Controller On following page ...
Page 79: ...71 From previous page On following page ...
Page 80: ...72 From previous page On following page ...
Page 81: ...73 From previous page ...
Page 95: ......