83
Appendix
* Appendix
Parameter (Shipment) Initialization Method
Parameters will be changed (initialized) to shipment parameters.
The compatible models are PCON, ACON and SCON.
Caution:
Please take note that if parameter (shipment) initialization is performed, user-set parameters will
be changed to shipment parameters.
Caution:
If software reset has not been executed, parameters have been rewritten to shipment
parameters but operation will not be performed with shipment parameters.
After the next reset or power-on, the parameters will be effective.
Input
for “Adjust No.” and press
the Return key.
The screen will change to the Parameter Init execution
confirmation screen.
Press the
key and press the Return key.
(When not performing parameter initialization, press the
key and press the Return key. The screen will
return to the Mode Select screen,)
The screen will change to the Software Reset screen.
Press the
key and press the Return key.
When the servo is ON, the screen will change to the
Servo OFF confirmation screen.
Press the
key and press the return key.
Parameters will be initialized and become shipment
parameters.
Since the servo is automatically turned OFF, it is not
required to turn SON input OFF.
Summary of Contents for CON-T
Page 1: ...Teaching Pendant Operating Manual First edition IAI America Inc ...
Page 2: ......
Page 4: ......
Page 6: ......
Page 14: ...6 6 2 External View External Dimensions ...
Page 78: ...70 Examples of PCON CY Controller On following page ...
Page 79: ...71 From previous page On following page ...
Page 80: ...72 From previous page On following page ...
Page 81: ...73 From previous page ...
Page 95: ......