85
Appendix
Code Message
name
Description
122 Allocate, multi-axes connect
Address was assigned when multiple axes were connected.
Assign each address only when one axis is connected.
133 Change to axis number
prohibit
In the case of the PCON-C/CG, ACON-C/CG, or SCON controller, the axis number is set
with the rotary switch on the front panel.
It cannot be set with the Teaching Pendant.
-
-
-
-
Change to axis number OK
Controller initialize OK
Home Change All Clear
IO function changed
These messages are displayed to confirm operation.
(They do not indicate an operation error or other abnormality.)
201 Emergency Stop
An emergency stop condition was detected. (This is not an error.)
It is displayed for PCON, ACON and SCON.
-
Emergency Stop
This message indicates an emergency stop condition. (This is not an error.)
It is displayed for PCON, ACON and SCON.
-
Motor voltage drop
This message indicates the motor drive power shut-off condition due to an open circuit
between the MPI terminal and MPO terminal.
(Note) If this message occurs when a circuit between the MPI terminal and MPO
terminal is closed, a controller failure is suspected.
-
ABS battery voltage drop
This message indicates that the battery voltage dropped when the power was turned
ON.
20A During movement, Servo OFF This message indicates that the servo ON signal (SON) was turned OFF by the PLC
while the actuator was moving and that the servo turned OFF and the movement was
disabled as a result.
20C During movement, CSTR-ON This message indicates that the start signal (CSTR) became “1” by the PLC while the
actuator was moving and that duplicate movement commands occurred as a result.
20D During movement, STP-OFF This message indicates that the temporary stop signal (*STP) was turned OFF by the
PLC while the actuator was moving and the movement was disabled as a result.
20E Soft limit over
This message indicates that a soft limit was reached.
210 HOME-ON during operation
This message indicates that a home return signal (HOME) became ON from PLC and
duplicate movement commands occurred during movement operation.
211 JOG-ON during operation
This message indicates that a home return signal (HOME) became ON from PLC and
duplicate movement commands occurred during movement operation.
220 Write in AUTO prohibited
This messages indicates that parameter writing operation was performed in the AUTO
mode of the PCON-C/CG, ACON-C/CG, or SCON controller.
221 Write in Monitor mode
prohibited
This message indicates that position data or parameter writing operation was performed
in the Monitor mode.
222 Operation in AUTO prohibited This message indicates that actuator movement operation was performed in the AUTO
mode.
223 Operation in Monitor mode
prohibited
This message indicates that actuator movement operation was performed in the Monitor
mode.
301
302
304
305
306
308
30A
30B
Over Run Error (M)
Framing Error (M)
SCIR-QUE OV (M)
SCIS-QUE OV (M)
R-BF OV (M)
Response Time Out (M)
Packet R-QUE OV
Packet S-QUE OV
These messages indicate an error in the serial communication with the controller.
Cause: [1] Garbage data due to the effect of noise
[2] Duplicate slave numbers when multiple controllers are controlled by serial
communication.
Action: [1] Adjust the wiring in a manner eliminating the effect of noise and review the
installation of equipment, etc.
[2] Change the slave numbers to avoid duplication.
If the message is still displayed after taking the above actions, please contact IAI.
Summary of Contents for CON-T
Page 1: ...Teaching Pendant Operating Manual First edition IAI America Inc ...
Page 2: ......
Page 4: ......
Page 6: ......
Page 14: ...6 6 2 External View External Dimensions ...
Page 78: ...70 Examples of PCON CY Controller On following page ...
Page 79: ...71 From previous page On following page ...
Page 80: ...72 From previous page On following page ...
Page 81: ...73 From previous page ...
Page 95: ......