GO-2400MC-PGE-1 | GO-2401MC-PGE-1 | User Manual (Ver. 1.0)
Preparation
- 31 -
When Controlling the Exposure Time using the Pulse Width of the Trigger Input Signal
Configure the settings as follows.
Item
Setting Value / Selectable Range
Trigger Selector
Frame Start
- Trigger Mode
On
- Trigger Source
Any
- Trigger Activation
Level High, Level Low
Exposure Mode
Trigger Width
1. Set
Exposure Mode
to
Trigger Width
. When you select
Trigger Width
,
Trigger Mode
will
automatically be set to
On
.
2. Set
Trigger Selector
to
Frame Start
. (Frame Start is the default setting.)
3. If necessary, change the Trigger Source and Trigger Activation settings.
Other Controls
In addition to exposure time, the following can also be controlled by external triggers. Select these
control operations in Trigger Selector.
Trigger Selector
Settings
Description
Acquisition Start
Start image acquisition.
Acquisition End
Stop image acquisition.
Acquisition Transfer
Start
Output acquired images at a specified timing. (Up to 7 frames for 8-bit, and up to 3
frames for 10-/12-bit.)