52
—
GO-5100M-USB / GO-5100C-USB
Item
Setting range
Default value
Description
Sequencer Command Index
—
1
Set this to change the Sequencer Index.
(Enabled only for Command Sequencer.)
Sequencer Set Start
—
1
Set the index number that is used when
executing [Sequencer Reset] in [Trigger
Sequencer] mode or [Command
Sequencer] mode.
Sequencer Reset
—
—
Reset the current index number to the
number configured in [Sequencer Set
Start].
j) Chunk Data Control
Configure Chunk Data function settings.
Chunk Mode Active
True, False
True
Enable/disable the Chunk Data function.
Chunk Selector
Chunk Image,
Chunk Offset X,
Chunk Offset Y,
Chunk Width,
Chunk Height,
Chunk Pixel Format,
Chunk Timestamp,
Chunk Line Status All,
Chunk Exposure time (us),
Chunk Gain All,
Chunk Gain Red,
Chunk Gain Blue,
Chunk Black Level All,
Chunk Sequencer Set
Active,
Chunk Frame Trigger
Counter,
Chunk Exposure Start
Counter,
Chunk Frame Start Counter,
Chunk Frame Transfer End
Counter,
Chunk Line Status All On
FVAL Start,
Chunk Device Temperature,
Chunk Device Serial
Number,
Chunk Device User ID
Image
Select the information you want added to
the image data.
Chunk Enable
True, False
—
Select whether to add the information to
the image data.
Default value: [Chunk Image] only “True”
k) Transport Layer Control
Display information on transport layer
control.
Payload Size
—
5065984
Display the payload size.
Device Tap Geometry
Geometry_1X1_1Y
Geometry_1X1_
1Y
Set the transmission method for each time
images are transmitted from the device
(TAP structure).
l) JAI Custom Control Pulse
Generators
Configure pulse generator settings.
Clock Pre-scaler
1 to 4096
165
Set the division value for the prescaler
(12-bit) using the pixel clock as the base
clock.
Pulse Generator Clock (MHz)
0.018127 to 74.25
0.45
Set the clock used for the pulse
generator.
This value is calculated based on the
Clock Pre-Scaler value.
Pulse Generator Selector
Pulse Generator 0
Pulse Generator
0
Select the pulse generator.