14. Supplemental Information
on Controller Menu Items
351
14.3.2 In the cases of SSEL, ASEL or PSEL Controllers
(1) Drive-source recovery request
[1] Case where a drive-source recovery request is required A drive-source recovery request is required
only in the following case:
When you specify any input port for the drive power cut-off release input signal (dedicated function),
drive power cut-off occurs.
recovery after the main cause of cut-off is solved.
[2] How to issue an operation pause release request An operation pause release request can be issued
using one of the following methods:
Set the I/O parameter (No.30 - No.45, No.251 - No.258) corresponding to the input port No. to 17
(specified input function value). (Refer to the list of I/O functions and I/O parameters in the SSEL,
ASEL or PSEL controller operation manual.)
Input the ON edge on the specified input port No.
From the software menu, execute Controller (C)
Request Drive Power Recovery (P).
(2) Operation pause release request
[1] An operation pause release request is required in any of the following methods: Only the following
case requires executing Request Release Pause:
When you set other parameter No.10 to 2, (emergency stop recovery release according to type =
continuous operation release [during automatic operation only], emergency stop during automatic
operation
recovery after release of emergency stop (operation pause release).
When you set other parameter No.11 to 2, (Deadman SW/Enable SW recovery according to type =
continuous operation recovery during automatic operation only), stop by Deadman SW or Enable
SW during automatic operation
recovery after emergency stop release (operation pause
release).
Specify any input port for the operation pause release signal (dedicated function). Set the I/O
parameter (No.30 - No.45, No. 251 - No.258) corresponding to the input port No. to 8 (specified
input function value). (Refer to the list of I/O functions and I/O parameters.)
OFF level input on the input port No. specified at automatic operation (pause operation)
recovery
after ON level input on the input port No. (operation pause release).
[2] How to issue an operation pause release request An operation pause release request can be issued
using one of the following methods:
•
Specify any input port for the operation pause release signal (dedicated function). Set the I/O
parameter (No.30 - No.45, No.251 - No.258) input port No. corresponding to the input port No. to 7
(specified input function value). (Refer to the list of I/O functions and I/O parameters.)
Input the ON edge on the specified input port No.
•
From the software menu, execute Controller(C)
Request Release Pause (L).
Note) If the case in [1] of (1) and any of the cases in [1] of (2) are present at the same time, a
drive-source recovery request must be issued first, followed by an operation pause release
request.
Summary of Contents for IA-101-TT-USB
Page 2: ......
Page 4: ......
Page 8: ......
Page 50: ...1 Before You Begin 42 1 4 Connection to Controller Fig 1 48 X SEL K J Type Controller ...
Page 52: ...1 Before You Begin 44 Figure shows example of TT Fig 1 50 Table Top Actuator TT TTA ...
Page 53: ...1 Before You Begin 45 Fig 1 51 X SEL KX JX Type Controller ...
Page 62: ...1 Before You Begin 54 Fig 1 60 ASEL Type Controller USB Cable ...
Page 63: ...1 Before You Begin 55 Fig 1 61 PSEL Type Controller USB Cable ...
Page 189: ...9 Symbol Edit Window 181 ...
Page 251: ...13 How to Reset an Absolute Encoder 243 Fig 13 38 Arm Length 120 Reference Position ...
Page 386: ...16 Appendix 378 ...
Page 391: ......