13. How to Reset an
Absolute Encoder
308
13.7 Simple absolute Unit for PSEL Controller (Option)
Perform an absolute reset for following conditions:
Connect to PSEL controller after starting simple absolute unit
Disconnect encoder cable of actuator from PSEL controller and reconnect them
Error No. 41C “ABS unit encoder error (2)”, and Error No.41D “ABS unit encoder error (3)” has occurred
Possible changes on home position, such as modifying home return and axis behavior related
parameter (No.1,6,10,11,12,21,38,42,43,44,46,47,50,51,66,67,68, Driver parameter No.26)
Please follow the instructions below to perform Absolute Reset by using “PC Software for X-SEL”.
13.7.1 Instructions of Absolute Reset
(1) Supply main power (DC24V) to controller and simple absolute unit.
If there is no adjustment item besides “ABS unit encoder error (2)”, 7 seg LED will display “E41C” when
panel unit is connected.
(2) Connect “PC Software for X- SEL” on online (Controller and PC with original connection cable).
(3) [Connection confirmation] dialog box will appear on screen. Configure connection port to your PC, then
click [OK] button. (Baud rate will be recognized automatically)
Fig. 13.161 Connection Confirmation Screen
Summary of Contents for IA-101-X-MW
Page 2: ......
Page 4: ......
Page 8: ......
Page 50: ...1 Before You Begin 42 1 4 Connection to Controller Fig 1 48 X SEL K J Type Controller...
Page 52: ...1 Before You Begin 44 Figure shows example of TT Fig 1 50 Table Top Actuator TT TTA...
Page 53: ...1 Before You Begin 45 Fig 1 51 X SEL KX JX Type Controller...
Page 62: ...1 Before You Begin 54 Fig 1 60 ASEL Type Controller USB Cable...
Page 63: ...1 Before You Begin 55 Fig 1 61 PSEL Type Controller USB Cable...
Page 189: ...9 Symbol Edit Window 181...
Page 251: ...13 How to Reset an Absolute Encoder 243 Fig 13 38 Arm Length 120 Reference Position...
Page 386: ...16 Appendix 378...
Page 391: ......