13. How to Reset an
Absolute Encoder
319
6) A Warning window shows up. Click on the “Yes”. Each operation for the push type absolute reset
starts.
Fig. 13.184 Warning Window
7) For the four-axis type, press Execute and proceed to “Removing”, and then take off the rotary axis
pressing absolute reset jig. At this time, make sure the work is conducted with the emergency stop
activated. Click on the “OK” button after the work is finished.
Fig. 13.185 Jig Removing Window
8) For the four-axis type, a warning window will be displayed. Click “Yes”.
The stopper pressing system absolute reset operation will be resumed.
Fig. 13.186 Warning Window
9) Once the push type absolute reset for all the axes is finished, the Information window will appear.
Click “OK” button.
Fig. 13.187 Information Window
10) Close the Push stopper position acquisition window by clicking “×” on the upper right side of the
window. Once the window is closed, the parameters start to be written automatically to the flash
ROM, and controller is rebooted by the software reset.
Summary of Contents for IA-101-X-MW
Page 2: ......
Page 4: ......
Page 8: ......
Page 50: ...1 Before You Begin 42 1 4 Connection to Controller Fig 1 48 X SEL K J Type Controller...
Page 52: ...1 Before You Begin 44 Figure shows example of TT Fig 1 50 Table Top Actuator TT TTA...
Page 53: ...1 Before You Begin 45 Fig 1 51 X SEL KX JX Type Controller...
Page 62: ...1 Before You Begin 54 Fig 1 60 ASEL Type Controller USB Cable...
Page 63: ...1 Before You Begin 55 Fig 1 61 PSEL Type Controller USB Cable...
Page 189: ...9 Symbol Edit Window 181...
Page 251: ...13 How to Reset an Absolute Encoder 243 Fig 13 38 Arm Length 120 Reference Position...
Page 386: ...16 Appendix 378...
Page 391: ......