3. Menu W
indow
82
(4) Program (S)
This menu lets you perform operations relating to programs. (Available only in the online mode.)
(Refer to “4. Program Edit Window.”)
[1] Edit (E)
Load a selected program from the controller for editing.
Cycle time can be measured in XSEL-RA/SA/RAX/SAX/RAXD/SAXD
(main CPU application version V1.10 and later).
[Refer to 4.5 Cycle Time Measurement]
[2] Copy/Move (C)
Copy/move (cut & paste) a program
[3] Clear (L)
Clear a program.
[4] Save to File (S)
Save a selected program or all programs to a file under a desired name.
[5] End All Operations (T)
End all programs and operations that are currently running/being
performed.
(5) Position (O)
This menu lets you operate position data. (Available only in the online mode.)
(Refer to “6. Position Data Edit Window.”)
[1] Edit (E)
Load position data from the controller for editing.
[2] Copy/Move (C)
Copy/move (cut & paste) position data.
[3] Clear (L)
Clear position data.
In the case of the X-SEL-R/S, RX/SX or RXD/SXD, RA/SA, RAX/SAX and RAXD/SAXD controller, the
position data items to be cleared can be selected on the Clear Position Data screen.
Fig. 3.15 Clear Position Data Screen
Clear All:
Clear all position data items (Axis 1 to 8, Arm 1 to 4, Arm 5 to 8, Vel, Acc, Dcl and
Comment).
Clear All but Comment: Clear all position data items except for comment (Axis 1 to 8, Arm1 to 4, Arm 5 to 8,
Vel, Acc and Dcl).
Clear Comment Only:
Clear only the comments among the position data.
Summary of Contents for IA-101-X-MW
Page 2: ......
Page 4: ......
Page 8: ......
Page 50: ...1 Before You Begin 42 1 4 Connection to Controller Fig 1 48 X SEL K J Type Controller...
Page 52: ...1 Before You Begin 44 Figure shows example of TT Fig 1 50 Table Top Actuator TT TTA...
Page 53: ...1 Before You Begin 45 Fig 1 51 X SEL KX JX Type Controller...
Page 62: ...1 Before You Begin 54 Fig 1 60 ASEL Type Controller USB Cable...
Page 63: ...1 Before You Begin 55 Fig 1 61 PSEL Type Controller USB Cable...
Page 189: ...9 Symbol Edit Window 181...
Page 251: ...13 How to Reset an Absolute Encoder 243 Fig 13 38 Arm Length 120 Reference Position...
Page 386: ...16 Appendix 378...
Page 391: ......