Table of Contents
1.
Outline······················································································································································· 1
1.1
CC-Link gateway unit··························································································································· 1
1.2
What is CC-Link··································································································································· 2
1.3
Application example of gateway unit···································································································· 3
1.4
Features ·············································································································································· 4
1.5
How to identify model ·························································································································· 6
2.
Specifications and name of each part ······································································································· 7
2.1
General specifications ························································································································· 7
2.2
External dimension drawing················································································································· 8
2.3
Name and function of each part··········································································································· 9
3.
Installation and Noise Elimination ··········································································································· 14
3.1
Installation Environment ···················································································································· 14
3.2
Power Supply ···································································································································· 14
3.3
Noise Elimination and Grounding ······································································································ 14
3.4
Installation ········································································································································· 16
4.
Wiring······················································································································································ 17
4.1
Overall Configuration ························································································································· 17
4.2
Input and output signal of gateway unit ····························································································· 20
4.3
Building of SIO communication network (SIO communication)·························································· 23
5.
Outline of CC-Link··································································································································· 32
5.1
Data communication ·························································································································· 32
5.2
Address assignment of master PLC ·································································································· 33
6.
Address configuration of gateway ··········································································································· 35
6.1
Gateway control signal ······················································································································ 35
6.2
Position data limit designation mode ································································································· 38
6.3
Position No. designation mode ·········································································································· 42
6.4
Position/speed/acceleration and deceleration designation ································································ 47
6.5
Push operation enable mode············································································································· 52
6.6
Simple direct value/position No. designation mode ··········································································· 58
7.
Contents of communication signal ·········································································································· 75
7.1
Outline of timing for communication signal ························································································ 75
7.2
Communication signal and operation timing ······················································································ 76
7.3
Command transmission and reception ······························································································ 88
Summary of Contents for RCM-GW-CC
Page 1: ...IAI America Inc CC Link RCM GW CC Gateway Unit Operation ManualFirst Edition...
Page 4: ......
Page 10: ...6 1 5 How to identify model RCM GW CC Basic model For CC Link Gateway unit...
Page 12: ...8 2 2 External dimension drawing Mounting dimension...
Page 78: ...74...
Page 82: ...78 Position data measurement value Present position 1 2 3 4 4 5 6 7...
Page 84: ...80 Speed acceleration and deceleration set value Actuator speed Speed n2 Speed n3 1 2 3...
Page 88: ...84 Command position No Completion position No 1 2 3 4 5 6...
Page 91: ...87...
Page 93: ...89...
Page 125: ...121 No 3 Axis 1 pause No 3 Axis 1 pause lamp No 3 Axis 1 STP...
Page 130: ...126...
Page 131: ......