60
PLC
output
⇒
Gateway unit
⇒
Each axis input Each axis output
⇒
Gateway unit
⇒
PLC input
Output register
Input register
Higher byte
Lower byte
Higher byte
Lower byte
Gateway control signal 0
Gateway control signal 1
Request command
Data 0
Data 1
Data 2
Data 3
Data 4 (Reserve)
Data 5 (Reserve)
Gateway control signal 0
Gateway control signal 1
Response command
Data 0
Data 1
Data 2
Data 3
Data 4 (Reserve)
Data 5 (Reserve)
Fixed region
(10 word)
(20 word)
(24 word)
(64 word)
(48 word)
(24 word)
4 word
1 word
Output (writing) Register=Word register
Position No. designated axis control signal
Input (writing) Register=Word register
Position No. designated axis status signal
1 word
3 word
Simple direct value axis control signal
Simple direct value axis control signal