92
6.
Operation:
Mode
Flow
Chart
93
6.9 User Adjustment
6.9.1 Homing Operation, Axis Number Setting, Calibration and Time Setting
• Execute homing.
• Set the axis number of the controller (PCON, ACON, ERC2, RCP-RSI, RCP-RM1, etc.).
Press the
key.
Caution:
Caution: Do not input any numeric value other than 1, 2, 3, 4, 6, 7, 8 and 5119 into Adjust
No. In the case of the RCP or RCP2 controller, 0 or 2 is set to parameter No. 25
(PIO pattern) (when there is no servo ON input), do not input 92 into Adjust No., either.
The controller will be inoperable due to no servo ON input.
v
If you input 1 into Adjust No. and press the Return
key, homing will be performed.
v
Axis number setting
Move the cursor to Adjust No. with the
key. Input
the axis number and press the Return key.
Input 2 into Adjust No. and press the Return key.
* In the case of the PCON-C/CG and other controllers
for which the axis number is set with the rotary switch
on the front panel of the controller, axis number
setting is not available.
• Perform the loadcell calibration (SCON-CA)
• Move to the clock setting window to set the current time
(SCON-CA, PCON-CA and ERC3 PIO Converter)
v
Calibration
Enter “6” to Adjustment No. and press the Return key
to perform a calibration.
(Setting is available only on SCON-CA.)
v
Time Setting
Enter “7” to Adjustment No. and press the Return key
to move to the clock window to set the current time.
(Setting is available only on SCON-CA, PCON-CA,
ACON-CA, DCON-CA and ERC3 PIO Converter.)
v
Maintenance Information
Enter “8” to Adjustment No. and press the Return key
to move to the Maint. Info window to set the
maintenance information.
(Setting is available only on SCON-CA, PCON-CA,
ACON-CA, DCON-CA, ERC3 (CON Mode (CN)) and
ERC3 PIO Converter.)
• Move onto the maintenance information screen and establish the maintenance information
settings. (SCON-CA, PCON-CA, ERC3 (CON Mode (CN)) and ERC3 PIO Converter)
Summary of Contents for Robo Cylinder CON-T
Page 1: ...Teaching Pendant Instruction Manual Tenth Edition CON T CON TG CON TGS IAI Corporation ...
Page 2: ......
Page 4: ......
Page 8: ......
Page 18: ... ...
Page 24: ...14 4 Functions and Specications of Teaching Pendant 4 2 External View External Dimensions ...
Page 97: ...87 6 Operation Mode Flow Chart Examples of PCON CY Controller On following page ...
Page 98: ...88 6 Operation Mode Flow Chart From previous page On following page ...
Page 99: ...89 6 Operation Mode Flow Chart From previous page On following page ...
Page 100: ...90 6 Operation Mode Flow Chart From previous page ...
Page 117: ......