42
43
6.
Operation:
Mode
Flow
Chart
(12) Gain Set (SCON-CA: Displayed in Version V1.10 or later, ACON-CA: Displayed in Version
V1.20 or later)
(Note) Setting is available only on SCON-CA or ACON-CA.
6 parameters necessary for Servo Gain Adjustment are gathered to make up 1 set.
4 types of settings are able to be registered and the servo gains can be switched over for each
positioning operation.
[Parameters constructed in 1 set]
• Servo Gain Number (Position Gain)
• Position Feed Forward Gain
• Speed Loop Proportion Gain
• Speed Loop Integration Gain
• Torque Filter Time Constant
• Current Control Band Number
Setting Operation after Positioning Complete
Parameter No.
0
Gain Set 0
7, 71, 31 to 33, 4
1
Gain Set 1
120 to 12
2
Gain Set 2
126 to 131
3
Gain Set 3
132 to 137
(13) Vibration Control No. (SCON-CA: Displayed in Version V1.10 or later, ACON-CA: Displayed in
Version V1.20 or later)
(Note) Setting is available only on SCON-CA or ACON-CA.
It controls the vibration (resonance) generated by the load due to the mounted actuator.
It possesses a capacity to deal with 3 types of vibration.
There are 3 parameters corresponds to 1 type of vibration and they are compiled in 1 set.
Set the parameter set corresponds to the position number necessary for the vibration control in
the position table.
Setting
Vibration Control Frequency (Specific Frequency)
Parameter No.
0
Standard Position Control (No Vibration Control)
-
1
Vibration Control Parameter Set 1
97 to 100
2
Vibration Control Parameter Set 2
101 to 104
3
Vibration Control Parameter Set 3
10 to 108
Caution:
(1) The vibration frequency that can be controlled (applicable specific frequency) is
from 0.5 to 30Hz.
(2) The vibration control is applicable only for the vibration generated by the load of
the actuator connected to this controller. Other vibrations cannot be controlled.
(3) The vibration control is applicable only for the vibration in the direction of the
actuator operation. Vibration in other directions cannot be controlled.
(4) The vibration control is not applicable for home-return and pressing operations.
() It does not corresponds to Pulse Train Input Mode.
(6) If the vibration frequency setting is low, the takt time may become long. The value
below approximately 6Hz makes the positioning finishing to take more than 150ms.
Summary of Contents for Robo Cylinder CON-T
Page 1: ...Teaching Pendant Instruction Manual Tenth Edition CON T CON TG CON TGS IAI Corporation ...
Page 2: ......
Page 4: ......
Page 8: ......
Page 18: ... ...
Page 24: ...14 4 Functions and Specications of Teaching Pendant 4 2 External View External Dimensions ...
Page 97: ...87 6 Operation Mode Flow Chart Examples of PCON CY Controller On following page ...
Page 98: ...88 6 Operation Mode Flow Chart From previous page On following page ...
Page 99: ...89 6 Operation Mode Flow Chart From previous page On following page ...
Page 100: ...90 6 Operation Mode Flow Chart From previous page ...
Page 117: ......