2
3
6.
Operation:
Mode
Flow
Chart
Operation
Screen
Reference
13. Input the current value during
push.
In this example, input 30%.
Input
and then press
the Return key.
Press the Return key again to
move the cursor to “Range.”
* For push control, refer to the
Controller Operating Manual.
14. Input the maximum push range
during push into the Range.
In this example, input 5 mm.
Input
and then press the
Return key.
Press the
key.
The screen will change to the
screen of Position No. 2 for
Push, LoTh and Range.
Summary of Contents for Robo Cylinder CON-T
Page 1: ...Teaching Pendant Instruction Manual Tenth Edition CON T CON TG CON TGS IAI Corporation ...
Page 2: ......
Page 4: ......
Page 8: ......
Page 18: ... ...
Page 24: ...14 4 Functions and Specications of Teaching Pendant 4 2 External View External Dimensions ...
Page 97: ...87 6 Operation Mode Flow Chart Examples of PCON CY Controller On following page ...
Page 98: ...88 6 Operation Mode Flow Chart From previous page On following page ...
Page 99: ...89 6 Operation Mode Flow Chart From previous page On following page ...
Page 100: ...90 6 Operation Mode Flow Chart From previous page ...
Page 117: ......