82
83
6. Operation: Mode Flow Chart
[Thresholds for Total Number of Movements and Total Travelled Distance]
You can set thresholds for total number of movements and total travelled distance in the parameters
specified below, to cause an alarm to generate when each threshold is exceeded.
Parameter No.
Name
147
Threshold for total number of movements
148
Threshold for total travelled distance
Message-level alarms
Alarm code
Name
Description
4E
Movements threshold
exceeded
This alarm generates when the total
number of movements exceeds the
threshold set in parameter No. 147.
4F
Travelled distance
threshold exceeded
This alarm generates when the
total travelled distance exceeds the
threshold set in parameter No. 148.
[Example of use for Total Drive Distance Times]
For an instance, it is recommended to have a grease supply on the scraper area every 300km in the
regular inspections when the drive distance exceeds 300km within 3 months for RCPW Rod Type
Actuator.
(Have a supply every 3 months for those which do not exceed it.)
In this case, set ‘300’ in Parameter No. 148 at the start of the first run, and an alarm notifies that
grease supply is required when the drive distance exceeds 300km.
After the grease supply, set multiple numbers of 300, such like 600, 900, in Parameter 148, and the
notification continues to be made for the timings of grease supply.
Summary of Contents for Robo Cylinder CON-T
Page 1: ...Teaching Pendant Instruction Manual Tenth Edition CON T CON TG CON TGS IAI Corporation ...
Page 2: ......
Page 4: ......
Page 8: ......
Page 18: ... ...
Page 24: ...14 4 Functions and Specications of Teaching Pendant 4 2 External View External Dimensions ...
Page 97: ...87 6 Operation Mode Flow Chart Examples of PCON CY Controller On following page ...
Page 98: ...88 6 Operation Mode Flow Chart From previous page On following page ...
Page 99: ...89 6 Operation Mode Flow Chart From previous page On following page ...
Page 100: ...90 6 Operation Mode Flow Chart From previous page ...
Page 117: ......