Ambient Self-Cleaning Dust Collector
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the
product described. The continual observance of these procedures will help increase your production and extend the life of the
equipment.
7
Air Supply
NOTE: The air supply should be between 60 and 90 PSI.
Do not exceed 90 PSI pressure.
1.
Attached compressed air to the unit for cleaning
purposes.
2.
A 1/4" NPT port is available for the connection of the
fume extractor to a compressed air supply.
3.
Place a pressure regulator inline ahead of the
connection to control the air pressure.
Junction Box
1.
Junction Box (120V): Solenoid and Indicator Run Light.
2.
Junction Box (460V): Motor.
1.
Flexible conduit: Solenoid 1.
2.
Flexible conduit: Solenoid 2 and Indicator Run Light.
3.
Flexible conduit: Motor.
Pre-drilled holes
1.
Pressure gauge tube (Pre-drilled holes: 1/2”).
2.
Motor (Pre-drilled holes: 3/4”).
3.
Solenoids and Indicator Run Light (Pre-drilled holes:
1/2”).