background image

IAP Boxair M1002

www.IAP-AirProducts.com

- 3 -

GENERAL INFORMATION

This instruction manual contains Boxair M1 mobile cassette filter unit use and maintenance information. Boxair M1 user should

become acquainted with contents of this publication to learn about unit construction, principles of operation and means of its safe

use. Manufacturer is not responsible for any consequences arising from the use of the unit against its intended purpose. Manufacturer

reserves the right to make changes to improve performance and operational qualities of the product in the future without prior notice.

important information

3D file or preview 

available

you will need 

tools, sub parts, 

accessories

keep away from 

source of high 

temperature

warnings, important 

notes

use respiratory 

protective equipment

protect from noise or 

eye damage

switch off before 

proceeding

GRAPHIC SYMBOLS

Store  in  dry  and  airy  rooms.  Place  in  a  position  ready  for 

operation. Protect against possibility of shifting during transport.

PRODUCT APPLICATION

Boxair M1002 mobile cassette filter unit is for sporadic and occasional use where there is no need of constant exhaust operation 

and it can be operated in the technical areas intended for permanent human habitation. Boxair M1002 is designed for extraction and 

purification of air from the dry dust with particular emphasis on the processes of welding, grinding, polishing, pouring, dispensing, 

grinding, cutting metals and plastics (excluding corrosive, chemically aggressive, explosive and flammable gaseous mixtures).

Due  to  the  extremely  harmful  to  the  health 

fine  dust,  located  inside  the  filter  and  on  filter 

cartridges,  all  work  associated  with  the  filter 

replacement  should  be  done  using  respiratory 

protective equipment.

Manufacturer does not recommend use of the unit for:

air  purification  from  dust  containing  asbestos,

cadmium, beryllium

air purification from wet dust

The user should make sure that the items listed below were included 

with the device set:

User’s manual,

metal mesh filter,

main cassette filter.

In the case of lack of any listed items, please contact the dealer.

EQUIPMENT ARRIVAL

Upon arrival the user needs to thoroughly inspect the equipment and make sure there was no damage caused by the shipping carrier.

If there is damage, the user needs to immediately contact their dealer.

If  the  package  or  device  are  damaged  upon  delivery 

the  user  needs  to  immediately  contact  the  dealer 

and draw up a protocol with the representative of the 

shipping company (many shipping companies consider 

acceptance  of  the  shipment  to  be  sufficient  to  avoid 

liability for damage caused during shipping).

Summary of Contents for BOXAIR M1002

Page 1: ...www IAP AirProducts com BOXAIR M1002 Mobile Filter Unit User s Manual...

Page 2: ...C SYMBOLS 3 GENERAL INFORMATION 3 PRODUCT APPLICATION 3 EQUIPMENT ARRIVAL 3 CONSTRUCTION 4 DIMENSIONS 4 TECHNICAL DATA 5 ARM INSTALLATION 5 FILTER REPLACEMENT 6 START UP WIRING DIAGRAM 6 MAINTENANCE 6...

Page 3: ...manent human habitation Boxair M1002 is designed for extraction and purification of air from the dry dust with particular emphasis on the processes of welding grinding polishing pouring dispensing gri...

Page 4: ...5 A Boxair M1 660 1047 1 660 719 5 160 660 160 660 719 2 A 1 6 C 1 6 www oskarairproducts com info oskarairproducts com Konstrukcja standardowa Parametry Akcesoria i opcje Opis Cz ci zamienne Nazwa ko...

Page 5: ...minal airflow cfm 700 Noise level dB A 68 Power supply V Hz 1x 120 60 Power rating HP 1 5 Energy usage A 2 7 Rotational speed RPM 2800 Metal mesh prefilter pcs 1 Cassette filter pcs 1 Weight without a...

Page 6: ...l out of the chamber A 242 177 G2 Prefilter 2000 hours B 242 205 F9 Cassette filter 400 hours Depending on application filter replacement times can differ START UP WIRING DIAGRAM All electrical work m...

Page 7: ...start the device No power supply Check the connection of the device check the power supply EC DECLARATION OF CONFORMITY The manufacturer Industrial Air Products 2544 Highway 70 East Cookeville TN 385...

Page 8: ...IAP Boxair M1002 888 372 0050 x4 Sales IAP AirProducts com www IAP AirProducts com...