ibaBM-SLM Manual
7.4
Status Display
Run, Link and Errors LEDs indicate the operational state.
LED
Status
Indication
L1: Run
(green)
blinking
off
power on and device functioning properly
no power
L2: Link
(yellow)
on
off
fast
blinking
telegrams received into dual-port-RAM from integrated SLB module
no telegrams received (either ibaBM-SLM bus inactive or SLB defect)
simulated telegrams received; (commissioning mode)
L3: Err
(red)
on
off
internal error in the device / no conversion table loaded /
error in dual-port-RAM
normal state; after resolution of error LED automatically resets
7.5
24 V DC Power Supply (X14)
The ibaBM-SLM device is powered by an external, unregulated 24 V DC (20-30 V DC)
with approx. 350 mA. Connect the +/-24 V DC terminal from the power supply to the 2-
pole Phoenix connector (supplied with device).
Please contact iba for additional DIN-rail or power supply requirements.
7.6
Fiber Optic connections (X32, X33) for ibaNet
The two fiber-optic interfaces connect the ibaBM-SLM with the ibaFOB-4i card in the
computer via fiber optic links.
62.5/125
m multi-mode fiber cables with ST termination are available from iba.
7.7
Notebook connections (X30, X31)
The two RJ11 connectors (X30, X31) provide a connection from ibaBM-SLM to a note-
book.
Each interface transports up to 64 64 binary signals (CH 01…64,
CH 65…128).
7.8
Status LEDs SIMOLINK bus
SIMOLINK
LED
Status
Indication
Link
(green)
blinking
Simolink Bus OK
Run (red)
blinking
Device OK
DPR
(orange)
blinking
Dual-port-RAM OK with respect to ibaBM-SLM Simolink Monitor device
For further information see the attached documentation “SLB SIMOLINK Board”
Issue 2.0
13