This chapter describes how to synchronize the local time of an ibaPADU-S-IT-16 system.
Other documentation
Moreover, an additionally connected ibaPDA measuring system can be synchronized via
any digital input (e.g. ibaPADU-S-IT-16 or a digital input module), please refer to
ibaPDA-V6 manual.
9.4
Make settings on the Website
The Website offers functions for diagnostics and settings of the device like passwords,
network settings, time settings, firmware update.
9.4.1
Accessing the Website
1.
Start a Webbrowser on the PC.
2.
Enter the URL into the address line (depending on the type of physical connection):
When connection established via
…
Then address
(URL) …
Ethernet TCP/IP interface (DHCP)
e.g. S-IT-16-000050
Ethernet TCP/IP interface (fixed IP address)
e.g. http://192.168.1.1
FO cable ibaNet 32Mbit Flex
e.g. http://172.16.0.101
Important note
ibaPADU-S using Windows 7, Windows Vista, Windows Server 2008
When working under Windows 7, Windows Vista or Windows Server 2008, you might not
get access to the Webpage although a connection is established. Check/change in the
Windows security settings the following parameters:
Path:
Control panel
– Administrative tools – Local Security Policy – Local Policies –
Security options
Parameters
:
Network security: LAN Manager authentification level
Value
:
"Send LM & NTLM responses"
You will find the registry entry on the
„ibaPADU-S Modular“ CD.