background image

 

 

 
 
 
 
 
 

SI-324-N 

Mid-Range Digital Signage Player 

 

 

 
 

User’s Manual 

 

Version 1.0 

(April 2020)

 

 

 

Summary of Contents for SI-324-N

Page 1: ...SI 324 N Mid Range Digital Signage Player User s Manual Version 1 0 April 2020...

Page 2: ...to the products described in this document without prior notice Every effort has been made to ensure the information in the document is correct however IBASE does not guarantee this document is error...

Page 3: ...rer s instructions may cause harmful interference to radio communications WEEE This product must not be disposed of as normal household waste in accordance with the EU directive of for waste electrica...

Page 4: ...ount of electrical current may still flow Use neutral cleaning agents or diluted alcohol to clean the device chassis with a cloth Then wipe the chassis with a dry cloth Vacuum the dust with a computer...

Page 5: ...R THAT FAIL DUE TO MISUSE ACCIDENT IMPROPER INSTALLATION OR UNAUTHORIZED REPAIR SHALL BE TREATED AS OUT OF WARRANTY AND CUSTOMERS SHALL BE BILLED FOR REPAIR AND SHIPPING CHARGES Technical Support Serv...

Page 6: ...Chapter 2 Hardware Installation Motherboard Information 9 2 1 Installation Replacement 10 2 1 1 Memory 12 2 1 2 Mini PCIe M 2 Cards 13 2 1 3 WiFi 3G 4G Antenna Installation 13 2 2 Pin Assignment for...

Page 7: ...6 4 5 Chipset Settings 34 4 6 Security Settings 36 4 7 Boot Settings 38 4 8 Save Exit Settings 39 Appendix 40 A SDR and HDR Resolution Support 41 A 1 Maximum SDR Resolution Clone Extended mode 41 A 2...

Page 8: ......

Page 9: ...1 Chapter 1 General Information The information provided in this chapter includes Features Packing List Accessories Specifications Product View Dimensions...

Page 10: ...ty technology helps eliminate the complexity of programming multi screen signage for users to enable them to project different display configurations according to their needs The SI 324 N features ene...

Page 11: ...General Information SI 324 N User Manual 3 1...

Page 12: ...expandable to 32 GB 1 x Mini PCIe slot for WiFi Bluetooth 4G LTE or capture card options 1 x M 2 E2230 slot for WiFi Bluetooth 4G LTE options 1 x M 2 M2280 for storage 1 3 Packing List Your product p...

Page 13: ...rs Super I O Fintek F81846AD Storage 1 x M 2 M2280 slot Power Requirement DC In 12V Power Supply 84W power adapter Watchdog Watchdog Timer 256 segments 0 1 2 255 sec min iControl Yes Chassis Aluminum...

Page 14: ...ve Humidity 10 90 at 45 C non condensing Vibration Protection Random operation 5grms 5 500 Hz All specifications are subject to change without prior notice Note The product performance relies on the s...

Page 15: ...k 4 USB 3 0 Ports 9 Wall Mount Brackets 5 USB 2 0 Port Be sure to press the EDID Button between the USB and HDMI connectors to acquire or change the EDID data when the connected display monitor cannot...

Page 16: ...8 SI 324 N User Manual 1 7 Dimensions Unit mm...

Page 17: ...9 Chapter 2 Hardware Installation Motherboard Information The information provided in this chapter includes Installation of memory M 2 and capture card Information and locations of connectors...

Page 18: ...screws as indicated below to remove the bottom chassis cover in order to install or replace the 1st memory module M 2 M2280 E2230 cards and HDMI capture card If you need to remove the motherboard inst...

Page 19: ...crews just indicated One memory slot can be seen at the right side The M 2 M2280 J13 E2230 J12 card sockets are on the left side To remove the motherboard or to install replace the 2nd memory the 10 s...

Page 20: ...nd outwards with your fingertips 1 Hold the memory module and align the key of the module with that on the memory slot 2 Gently push the module in an upright position unitl the ejector tabs of the mem...

Page 21: ...the M 2 network card with an M3 screw Mini PCIe M 2 2 1 3 WiFi 3G 4G Antenna Installation Thread the WiFi 3G 4G antenna extension cable through an antenna hole of the front I O cover and fasten the a...

Page 22: ...3 12V 4 12V 2 3 Pin Assignment for COM1 RS 232 Port COM1 port is jumper less and configurable in BIOS Pin Assignment Pin Assignment 1 DSR Data set ready 6 DCD Data carrier detect 2 Ground 7 DTR Data...

Page 23: ...ral metal pins with a non conductive base mounted on the circuit board Jumper caps are used to have the functions and features enabled or disabled If a jumper has 3 pins you can connect either PIN1 to...

Page 24: ...16 SI 324 N User Manual 2 5 Jumper Connector Locations on Motherboard Motherboard MBD324 MBD324 top and I O MBD324 bottom...

Page 25: ...rt CN9 Audio Line Out jack CN10 DC power input connector 1 CN11 COM1 RS 232 port 2 COM1 Power button SW1 Clearing EDID button SW2 Full Size Mini PCIe slot J7 SIM card socket J10 DDR4 memory slot J4 J1...

Page 26: ...2 6 1 COM1 RS 232 Power JP2 Function Pin closed Illustration 12V 1 3 RI default 3 4 5V 3 5 2 6 2 Clearing CMOS Data J2 Function Pin closed Illustration Normal default 1 2 Clear CMOS 2 3 6 5 2 1 6 5 2...

Page 27: ...iguration SI 324 N User Manual 19 2 2 6 3 System Fan Power Connector J8 Pin Signal Name 1 Ground 2 12V 3 Rotation detection 2 6 4 CPU Fan Power Connector J9 Pin Signal Name 1 Ground 2 12V 3 Rotation d...

Page 28: ...20 Chapter 3 Driver Installation The information provided in this chapter includes AMD Radeon Graphics Driver Installation HD Audio Driver Installation LAN Driver Installation...

Page 29: ...website www ibase com tw Register as a member of our website to download all the necessary drivers and extract for installation 3 2 AMD Radeon Graphics Driver Installation 1 Run the Setup exe file 2 A...

Page 30: ...3 HD Audio Driver Installation 1 Run the Setup exe file 2 On the Welcome screen of the InstallShield Wizard click Next for installation 3 When the driver is completely installed restart the computer f...

Page 31: ...river Installation 1 Run the Setup exe file 2 On the Welcome screen of the InstallShield Wizard click Next 3 Accept the license agreement and click Next to continue 4 When the driver is completely ins...

Page 32: ...apter describes the different settings available in the AMI BIOS that comes with the board The topics covered in this chapter are as follows Main Settings Advanced Settings Chipset Settings Security S...

Page 33: ...Test will continue with its test routines thus preventing you from invoking the Setup If you still need to enter Setup restart the system by pressing the Reset button or simultaneously pressing the Ct...

Page 34: ...date Use the Tab key to switch between the data elements System Time Set the time Use the Tab key to switch between the data elements 4 4 Advanced Settings This section allows you to configure improve...

Page 35: ...es Disables BIOS ACPI auto configuation Enable Hibernation Enables Disables system ability to hibernate OS S4 Sleep State This option may not be effective with some operating systems ACPI Sleep State...

Page 36: ...e delay Temperature Guardian Enables Disables the temperature guardian Schedule Slot 1 2 Sets up the hour minute for system powe on Important If you would like to set up a schedule between adjacent da...

Page 37: ...r Manual 29 4 4 4 4 F81846 Super IO Configuration BIOS Setting Description Serial Ports Configuration Sets parameters of Serial Port COM Enables Disables the serial port and select an optimal setting...

Page 38: ...Control Disable or set fan control for CPU_FAN2 at 50 C 60 C 70 C or 80 C Temperatures Voltages These fields are the parameters of the hardware monitoring function feature of the motherboard The valu...

Page 39: ...1 4 4 4 6 CPU Configuration BIOS Setting Description Node 0 Information Displays the memory information related to Node 0 4 4 7 AMI Graphic Output Protocol Policy BIOS Setting Description Output Selec...

Page 40: ...BIOS Setting Description Network Stack Enables Disables UEFI Network Stack 4 4 9 CSM Configuration BIOS Setting Description CSM Support Enables Disables CSM support Network Controls the execution of U...

Page 41: ...wnership change should be claimed by XHCI driver USB Mass Storage Driver Support Enables Disables the support for USB mass storage driver USB Transfer time out The time out value for Control Bulk and...

Page 42: ...34 SI 324 N User Manual 4 5 Chipset Settings BIOS Setting Description Sourth Bridge South Bridge parameters SB USB Configuration Options for SB USB configuration...

Page 43: ...BIOS Setup SI 324 N User Manual 35 4 4 5 1 SB USB Configuration BIOS Setting Description XHCI0 XHCI1 Ports Enables Disables XHCI0 XHCI1 ports...

Page 44: ...er Manual 4 6 Security Settings BIOS Setting Description Administrator Password Sets an administrator password for the setup utility User Password Sets a user password Secure Boot Custimizable secure...

Page 45: ...s activated when it is enabled when the Platform Key PK is enrolled the System mode is user deployed and CSM is disabled Secure Boot Customization Customizable Secure Boot mode In Custom mode Secure B...

Page 46: ...FF means indefinite waiting Bootup NumLock State Selects the keyboard NumLock state Quiet Boot Enables Disables Quiet Boot option Boot Mode Select Select boot mode as Legacy or UEFI Boot Option Priori...

Page 47: ...tem after saving the changes Discard Changes and Reset Resets system setup without saving any changes Save Changes Saves changes done so far to any of the setup options Discard Changes Discards change...

Page 48: ...he mapping addresses of peripheral devices and the sample code of watchdog timer configuration SDR and HDR Resolution Support AMD Eyefinity Multiple Displays I O Port Address Map Interrupt Request Lin...

Page 49: ...60 4 displays 2160p60 Single Channel 1 display 2880p60 4320p30 2 displays 2160p60 3 displays 1440p60 2160p30 4 displays 1440p60 2160p30 A 2 Maximum HDR Resolution Clone Extended mode Dual Channel 2 di...

Page 50: ...finity Using Quick Setup B 1 1 AMD Eyefinity Quick Setup with All Displays This section describes how to set up AMD Eyefinity with the Quick Setup option where all the connected displays will be part...

Page 51: ...splay configuration Note At the time of writing Advanced Setup for configuring Eyefinity is available However this feature is not supported Do not confuse with Try Advanced Setup see below picture whi...

Page 52: ...Displays Arrange the position of each display in the AMD Eyefinity Display Group Refer to the next section Arrange Displays after Eyefinity Quick Setup for details Try Advanced Setup Additional settin...

Page 53: ...onfiguring Eyefinity with only a portion of the connected displays is not allowed For example setting up 3 x 1 Eyefinity with 4 connected displays is not possible with Eyefinity Quick Setup The follow...

Page 54: ...Using Try Advanced Setup Try Advanced Setup becomes available after Eyefinity Quick Setup is complete see above picture It offers customization for the Eyefinity Display Group created with options su...

Page 55: ...ar once Radeon Additional Settings launches 3 Check the Position the Windows taskbar on a single display option and click Continue 4 To move the Taskbar simply drag and drop it to the desired display...

Page 56: ...lays after Eyefinity Quick Setup Step 2 to 4 to complete re arranging the displays in an Eyefinity Display Group B 2 3 Resize Desktop When displays in an AMD Eyefinity Display Group are configured to...

Page 57: ...ll displays in the group to the original display configuration To disable the Eyefinity Display Group 1 Click Try Advanced Setup under Eyefinity tab in AMD Radeon Settings after Eyefinity Quick Setup...

Page 58: ...of an AMD Eyefinity Display Group to be changed to any resolution that is listed in the Custom Resolution drop down menu Once the desired Custom Resolution is chosen in Customize Eyefinity Desktop Re...

Page 59: ...n your displays and cannot be changed Use the Custom Resolution drop down menu to select from a list of supported resolutions 4 Select the preferred resolution from the Custom Resolution drop down men...

Page 60: ...0000A0 0x000000A1 Programmable interrupt controller 0x00000000 0x000003AF PCI Express Root Complex 0x00000000 0x000003AF Direct memory access controller 0x000003E0 0x00000CF7 PCI Express Root Complex...

Page 61: ...x00000C6C 0x00000C6C Motherboard resources 0x00000C6F 0x00000C6F Motherboard resources 0x00000CD0 0x00000CD1 Motherboard resources 0x00000CD2 0x00000CD3 Motherboard resources 0x00000CD4 0x00000CD5 Mot...

Page 62: ...er 1 10 Microsoft IRQ 4294967279 AMD USB 3 10 eXtensible Host Controller 1 10 Microsoft IRQ 4294967278 AMD USB 3 10 eXtensible Host Controller 1 10 Microsoft IRQ 4294967277 AMD USB 3 10 eXtensible Hos...

Page 63: ...Q 4294967274 AMD USB 3 10 eXtensible Host Controller 1 10 Microsoft IRQ 4294967273 AMD USB 3 10 eXtensible Host Controller 1 10 Microsoft IRQ 4294967272 AMD USB 3 10 eXtensible Host Controller 1 10 Mi...

Page 64: ...IS PROVIDED AS IS WITHOUT WARRANTY OF ANY KIND EITHER EXPRESSED OR IMPLIED INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND OR FITNESS FOR A PARTICULAR PURPOSE include dos h...

Page 65: ...x20 Set_F81846_Reg 0xF5 bBuf start counting void DisableWDT void unsigned char bBuf Set_F81846_LD 0x07 switch to logic device 7 bBuf Get_F81846_Reg 0xFA bBuf 0x01 Set_F81846_Reg 0xFA bBuf disable WDTO...

Page 66: ...UNLOCK outportb F81846_INDEX_PORT F81846_UNLOCK void Lock_F81846 void outportb F81846_INDEX_PORT F81846_LOCK void Set_F81846_LD unsigned char LD Unlock_F81846 outportb F81846_INDEX_PORT F81846_REG_LD...

Page 67: ...ABILITY AND OR FITNESS FOR A PARTICULAR PURPOSE ifndef F81846_H define F81846_H 1 defineF81846_INDEX_PORT F81846_BASE defineF81846_DATA_PORT F81846_BASE 1 defineF81846_REG_LD 0x07 define F81846_UNLOCK...

Reviews: