AS1375MP-960
Page 20
20/11/2006
Salt Setting
The Salt Setting refers to the total amount of salt, in
pounds, that the control uses during a regeneration of
the resin bed. The amount of salt used in a regenera-
tion determines the amount of water that the condi-
tioner softens between regenerations. If this setting is
changed, it may be necessary to change the Capacity
Setting as well. Refer to Table2 for SALT and
CAPAC-ITY information.
Complete the following steps to change the Hardness
Setting:
1. Press the down arrow
ò
button until the green
light next to the SALT legend is on. The display
shows a number with a zero or a five to the right
of the decimal point. No other number can be
entered in this position. The setting range is (0.1
to 25.5 kilograms for metric).
2. Press the
SET
button and the minute number on
the display starts flashing. If you want to change
this number, press the up
ñ
button to increase
the number or the down arrow
ò
button to
decrease the number.
To skip the number without changing, press the
left arrow
ï
button.
3. When the number is correct, press the left arrow
ï
button. The first number stops flashing and the
next number starts flashing. You can only change
the flashing number.
4. Continue changing numbers until you reach the
desired setting.
5. Press the
SET
button. The number stops flashing
and the control accepts the new setting. After
approximately 30 seconds, the control starts alter-
nating the display between TIME OF DAY and
CAPACITY.
Note:
If a beep sounds, the new setting is not
accepted.
If the control does not display this setting, your dealer
has disabled it. Some municipalities require that the
Salt Setting not be adjustable. Contact your dealer for
additional information.
Capacity Setting
The Capacity Setting refers to the kilograins of hard-
ness that can be removed by the conditioner between
regenerations. Your dealer entered this setting when
the control was installed. Please consult with your
dealer before changing this setting.
Complete the following steps to change the Hardness
Setting, refer to Table 1:
1. Press the down arrow
ò
button until the green
light next to the SALT legend is on. The setting
range is (0.1 to 14.00 kilograms for metric).
2. Press the
SET
button and the minute number on
the display starts flashing. If you want to change
this number, press the up
ñ
button to increase
the number or the down arrow
ò
button to
decrease the number.
To skip the number without changing, press the
left arrow
ï
button.
3. When the number is correct, press the left arrow
ï
button. The first number stops flashing and the
next number starts flashing. You can only change
the flashing number.
4. Continue changing numbers until you reach the
desired setting.
5. Press the
SET
button. The number stops flashing
and the control accepts the new setting. After
approximately 30 seconds, the control starts alter-
nating the display between TIME OF DAY and
CAPACITY.
Note:
If a beep sounds, the new setting is not
accepted.
Reminder:
Whenever the HARDNESS or CAPACITY
setting is changed, you should regenerate the condi-
tioner by pressing the REGEN button.
If the control does not display the Capacity Setting,
your dealer has disabled it. Some municipalities
require that the Salt Setting be disabled which also
disables the Capacity Setting. Contact your dealer for
additional information.