background image

AS1375MP-960

 

Page 23 

20/11/2006

 

 

 

 
 

Manual Valve Operation 

 
The camshaft may rotate manually to actuate the 
valve functions for service purposes. 
1.  Unplug the wall-mounted transformer. 
2.  Remove the rear cover by pulling back on the tab 

provided on the cover. Next, lift the rear cover off 
the valve, Figure 2. 

3.  Rotate the camshaft COUNTERCLOCKWISE 

until the appropriate valve is opened by the 
camshaft lobe. Use the regeneration cycle 
indicator as a guide to which valve discs are 
open. 

4.  When the service is complete, rotate the 

camshaft so the regeneration cycle indicator is 
pointing to the end of the refill cycle. 

5.  Reinstall cover, reconnect electric power, and 

reset the time of day. 

6.  The display will shoe Err3 and the motor will start 

up. After approximately 5 minutes, the indicator 
will point to REGENERATION COMPLETE and 
the control starts alternating the display between 
TIME OF DAY and CAPACITY. 

7.  The conditioner is now in operation. 
 

Additional Features 

 
When your dealer installs the conditioner, the control 
settings are adjusted to meet your soft water needs. 
However, there are additional features which your 
dealer can incorporate into the control. These 
features are: 12 or 24-Hour Clock, Metric Units of 
Measure, Calendar Override and Immediate 
Regeneration. 
 

12 or 24-Hour Clock 

 
The standard clock is a 12-hour with a PM indicator. 
An optional 24-hour clock without a PM indicator is 
available. Time can be set from 00:00 to 23:59. This 
option applies to both the Time of Day and Time of 
Regeneration settings. 
 

Metric Units of measure 

 
The standard units of measure are U.S. values. Hard-
ness is in grains per gallon, Salt in pounds, and 
Capacity is in kilograins. The metric option changes 
these to milligrams per litre, kilograms, and Kilograms 
respectively. All controls settings use the metric 
values when the metric option is selected. 
 

Calendar Override 

 
The Calendar Override option is a method of forcing 
the control to regenerate after a preset number of 
days, is normal demand-based regeneration does not 

occur first. This feature is not set at the factory; your 
dealer can set it at 1 to 30days. 

 

 
 
 
 
 

Immediate Regeneration 

 
The control is factory set to wait until the Time of Day 
reaches the Time of Regeneration to begin a regen-
eration. Your dealer can program the controller to 
regenerate any time the capacity remaining reaches 
zero. Remember that you do not have soft water 
available during any regeneration. 
  

Disinfection of Water Conditioners 

 
The construction materials of the water conditioner 
system do not support bacterial growth or 
contaminated the water supply. However, we 
recommend that the conditioners be disinfected after 
installation and before the conditioners are used to 
treat potable water. In addition, a conditioner can 
become fouled with organic matter during normal 
usage or with bacteria from the water supply. Periodic 
disinfection is recommended for all conditioners.  
 
Use one of the following methods of disinfection 
based on operating conditions, style of conditioner, 
type of ion exchange, and disinfectant available. 
 

Sodium Hypochlorite 

 
Sodium Hypochlorite, 5.25% solutions, can be used 
with polystyrene resin, synthetic gel zeolite, 
greensand, and bentonites and are available under  
trade names such as Chlorox, Linco, Bo Peep, White 
Sail and Eagle Brand Bleach. Adjust the dosage if 
stronger commercial solutions are used. 
 
The recommended dosage for 5.25% solution is: 

 

Polystyrene resin: 1.2 fluid ounces per cubic foot. 

 

Non-resinous exchangers: 0.8 fluid ounces per 
cubic foot. 

 

Calcium Hypochlorite 

 
Calcium Hypochlorite, 70% available chlorine, is 
available in several forms including tablets and 
granules. These solid materials can be used directly 
without dissolving before application. The recom-
mended dosage for Calcium Hypochlorite is two 
grains (approx. 0.1 ounce) per cubic foot. 
 
Complete the following steps to disinfect the 
conditioner:  
1.  Add the Calcium Hypochlorite to the brine well of 

the brine tank. Make sure that he brine tank has 

Summary of Contents for AS1375MP-960

Page 1: ...ON OPERATING INSTRUCTIONS Model AS1375MP 960 Serial No Telephone 07 3219 2233 Facsimile 07 3219 2266 Email sales ibcwater com au Website www ibcwater com au FILTRATION WATER TREATMENT PRODUCTS for com...

Page 2: ...25 12 75 93 0 85 0 60 1 6 Peak flow not recommended for extended periods of time Brine Tank Poly moulded or fibreglass construction complete with lid Brine Valve Plastic construction Operating Pressur...

Page 3: ...H THE TOP STRAINER SUPPLIED LOOSE IT IS IMPORTANT THAT THIS STRAINER IS ASSEMBLED TO THE VALVE DURING INSTALLATION THE LENGTH OF THE INTERNAL RISER PIPE IS FACTORY ADJUSTED FOR THE TANK SIZE PROVIDED...

Page 4: ...rogramming For your Application Units of Measure Notes P1 Time of day AM or PM 1 00 to 12 59 1 Current time Hour minute Range depends on value selected for P13 Enter the current time P2 Time of day Of...

Page 5: ...erous to walk on STEP 5 Clean top of neck and threads of all traces of resin Remove the plastic cap fitted in Step 3 taking care not to raise the distributor pipe NEVER shorten the length of the distr...

Page 6: ...nded The following will have to be programmed into the control Current time of day Hardness of your local water supply Plug transformer into main GPO Push lead end into socket underneath the front of...

Page 7: ...k Using the buttons key in the current second hour figure In example 11 25 Key in 1 Press the key the first hour digit will blink Using the buttons key in the first hour figure In example 11 25 Key in...

Page 8: ...k Using the button only keep on pressing slowly until a little dot appears in the top left hand corner of the display under PM if the display is blinking and shows 1 keep on pressing button until 0 ap...

Page 9: ...ck the settings in the program wait till the green light moves to TIME OF DAY Check time of day is correct Press button to TIME OF REGENERATION 2 00 should be displayed Press button to HARDNESS the ha...

Page 10: ...r is being expelled along with the water close off the mains water inlet valve Slowly turn the camshaft anti clockwise till the white line in the round window comes around to the REFILL position Turn...

Page 11: ...brine tank or cabinet will be refilled with the correct amount of water necessary to dissolve the salt required Open the outlet mains valve and close off the bypass valve and check the treated water a...

Page 12: ...AS1375MP 960 Page 12 20 11 2006 Water Conditioning Control System Installation Operating and Maintenance Manual Series 255 Valve 960 Control...

Page 13: ...neration Manual Regeneration Care of Your Water Conditioner 20 General Cleaning the Injector Injector Screen Maintaining the Drain Line Manual Valve Operation 22 Additional Features 22 Disinfection of...

Page 14: ...ree performance The metering system has only one moving part a rotating turbine that measures water usage Time and Capacity Display During normal conditioning operation the correct time of day alterna...

Page 15: ...held closed by water pressure and are leak tight Valve seats are in a vertical position which is the position least vulnerable to plugging System operation cannot get out of phase or sequence The cont...

Page 16: ...s Water Line Connection A bypass valve system must be installed to provide for occasions when the water conditioner must is by passed for hard water or for servicing The most common bypass systems are...

Page 17: ...y freezes with the REGEN TIME REMAINING information After the first regeneration is completed the second regeneration begins immediately The display will alternate between the TIME OF DAY and REGEN TI...

Page 18: ...ing a regeneration of the water conditioner Time of Regeneration can be set for any time AM or PM Note The control may be programmed for an immed iate regeneration option In this case the control does...

Page 19: ...bers until you reach the desired setting 5 Press the SET button The number stops flashing and the control accepts the new setting After approximately 30 seconds the control starts alter nating the dis...

Page 20: ...his setting your dealer has disabled it Some municipalities require that the Salt Setting not be adjustable Contact your dealer for additional information Capacity Setting The Capacity Setting refers...

Page 21: ...in this manual or contact your dealer for more information about these options The factory setting for Time of Regeneration is 2 00 AM You can change this time Refer to the Time of Regeneration sectio...

Page 22: ...caution note 12 Reinstall cover reconnect electric power and reset the time of day 13 Slowly open the water supply valve or return the bypass valve s to the not in bypass position Maintaining the Drai...

Page 23: ...ption is a method of forcing the control to regenerate after a preset number of days is normal demand based regeneration does not occur first This feature is not set at the factory your dealer can set...

Page 24: ...sed to treat potable water Refer to the Disinfection of Water Conditioners section in this manual Complete the following steps to place the conditioner into operation 1 Remove the rear valve cover by...

Page 25: ...ts refer to the Troubleshooting section in this manual When the water is being drawn fro the brine tank rotate the camshaft COUNTERCLOCKWISE until the indicator points to REGEN COMPLETE Run water from...

Page 26: ...r Tank 1000215 No 14 for 14 in Diameter Tank 7 1030502 Ball Flow Control 1 8 Injector Assy With O rings 1 1032970 A Injector White 1032971 B Injector Blue 1032972 C Injector Red 9 Injector Cap With O...

Page 27: ...AS1375MP 960 Page 27 20 11 2006 C Meter Adapter Bypass Valve and Piping Boss Bypass Valve 3 960 Control...

Page 28: ...611 3 4 in BSPT Brass Pipe Adaptor Kit 1 1001610 1 in NPT Brass Pipe Adaptor Kit 1 1001612 1 in BSPT Brass Pipe Adaptor Kit 1 Not Shown Code Part No Description Qty Piping Boss 1 Kit Piping Boss Inclu...

Page 29: ...ic Failure Improper start of regeneration limit switch closed when it should be open Improper finish of regeneration limit switch open when it should be closed Improper control settings Cause Control...

Page 30: ...Loss of power to the system a Transformer unplugged b Fuse blown circuit breaker open or circuit switched off a Connect the power b Correct the electrical problem 4 Control does not regenerate automa...

Page 31: ...alent Manual Regeneration Guest Cycle Forces the control to regenerate by pressing the REGEN button Regeneration Includes the backwash brine draw and fresh water rinse steps necessary to prepare the r...

Page 32: ...AS1375MP 960 Page 32 20 11 2006...

Page 33: ...f approximately 20ppm based on a sample volume of 10mls Other hardness test kits are available for more accurate testing eg Hardness Tablets Directions Take a 50ml sample of water in a screw capped bo...

Reviews: