AST0715-940

Page 

10

Introduction

Thank you for purchasing a water conditioner system
featuring the Series 255 with a model 940 Control.

The Model 940 Control provides dependable time
clock based operation. The Series 255 valve
combines simplicity with reinforced NORYL *
construction to provide an uncommonly reliable
appliance. The inherent quality of the system means
a long life of efficient, trouble-free soft water. If
maintenance becomes necessary, the Series 255/940
Control offers a unique separation capability
illustrated in the Service section of this manual.

Superior design

 

Single synchronous electric motor 

provides all

the power for the clock and the operation of the
control.

 

Electrical wiring is factory assembled. 

System

cannot be connected incor

rectly.

 

Program clock 940 (timer) and 960 Demand
system are interchangeable. 

Both units provide

guest regeneration capability.

 

System may be indexed manually with or
without power 

to any one of its service or

regeneration positions. Legend on timer faceplate
indicates control valve position.

 

No moving parts in water stream 

means no

close tolerance parts subject to fouling. Thus, the
system is especially effective on iron-bearing
water.

 

No dynamic seals 

that could cause leakage

through wear or fatigue.

 

Control accepts NORYL* or brass manifold or
modular bypass valve without modification,

offering complete versatility and easy plumbing
for any installation.

 

Brining control valve built into system

eliminates need for any brine valve.

 

Drain flow control 

is built into the valve to

control backwash and fast rinse flow rates.

 

NORYL is a trademark of GE Plastics.

Superior Operation

 

Direct acting system 

functions independently of

water pressure. No pistons or diaphragms that
require a minimum water pressure to operate.

 

Five-cycle operation 

provides for down flow

service, up flow backwash, down flow brining,
down flow slow and fast rinse. A sixth position is
included for timed refill of the brine tank.

 

Valve discs are held closed by water pressure

and therefore, are leak tight. The sealing forces
are increased as the water pressure is increased.
Valve seats are in a vertical position, which is
design position least vulnerable to plugging.

 

System operation cannot get out of phase 

or

sequence. The control always returns to a fixed
service position of regeneration regardless of
where in the regeneration cycle it was started.

 

Bypass (unconditioned) water is automatically
available 

during regeneration.

Installation

All plumbing and electrical connections must conform
to local codes. Inspect the unit carefully for carrier
shortage or shipping damage.

Location Selection

 

Locate unit as close to a drain as possible

 

If supplementary water treating equipment is
required, make sure that adequate additional
space is available. Locate the brine tank in an
accessible place so that salt can easily be added.

 

Do not install any unit closer than 10ft (3m) of
piping between the outlet of the water conditioner
and the inlet of the water heater. Water heaters
can transmit heat back down the cold water pipe
into the control valve. Hot water can severely
damage the controller.

A 10ft (3m) total pipe run (including bends, elbows
etc) is a reasonable distance to prevent hot water
damage. A positive way to prevent hot water from
flowing from a heat source to the conditioner is to
install a check valve in the soft water piping from the
conditioner. If a check valve is installed, make sure
that the water-heating unit is equipped with a properly
rated temperature and pressure safety relief valve.
Always conform to local codes.

 

Do not locate the unit in an area where the temp
ever falls below 34ºF (1ºC) or over 120ºF (49ºC).

 

Do not install the unit near acid or acid fumes.

 

Do not expose the unit to petroleum products.

Summary of Contents for AST0715-940

Page 1: ...ION OPERATING INSTRUCTIONS Model AST0715 940 Serial No Telephone 07 3219 2233 Facsimile 07 3219 2266 Email sales ibcwater com au Website www ibcwater com au FILTRATION WATER TREATMENT PRODUCTS for com...

Page 2: ...oximately 20ppm based on a sample volume of 10mls Other hardness test kits are available for more accurate testing eg Hardness Tablets Directions Take a 50ml sample of water in a screw capped bottle A...

Page 3: ...in litres call D For household situations allow 250 litres per person per day CALCULATION N 1000 x C D x H Select nearest lower whole number If necessary consult your dealer or IBC Water Treatment for...

Page 4: ...es AST0715 940 525 1 1050 3 6 15 25 12 15 27 0 70 0 50 1 2 CABINET BRINE CHAMBER POLY MOULDED Operating Pressure 140 690 kPa Temperature 5o x 50o C Electrical 240V 50Hz 3 watts maximum WARNING A press...

Page 5: ...t outlet pipes and drain line to control valve as per Instruction Booklet page 5 figure 3 Note The softener is supplied with the Autotrol Series 156 Bypass Valve as standard STEP 2 Remove lid from bri...

Page 6: ...TOP STRAINER SUPPLIED LOOSE IT IS IMPORTANT THAT THIS STRAINER IS ASSEMBLED TO THE VALVE DURING INSTALLATION THE LENGTH OF THE INTERNAL RISER PIPE IS FACTORY ADJUSTED FOR THE TANK SIZE PROVIDED DO NOT...

Page 7: ...the timer at the left hand side The Transformer is only suitable for indoor mounting When ordering spare parts Advise that the Timer is the low voltage model Salt Dial Indicator Knob Clock Dial Calend...

Page 8: ...AST0715 940 Page 8 Water Conditioning Control System Installation Operating and Maintenance Manual Series 255 Valve 940 Control...

Page 9: ...cing Conditioner into Operation 13 Adjustment of Timer 14 Special Features of Timer Adjustment of Brine Control 14 How to Set the Salt Dial Service 15 Removing the Timer Assembly Removing the Valve As...

Page 10: ...ve cycle operation provides for down flow service up flow backwash down flow brining down flow slow and fast rinse A sixth position is included for timed refill of the brine tank Valve discs are held...

Page 11: ...rol Bypass Valve optional Air Check Brine Tube Fitting Connection 1 4 Figure 2 Tank Adaptor Tank Tread 2 1 2 8 male NPSM Drain Connection 3 8 or 1 2 NPT or BSPT Outlet Connection 3 4 or 1 NPT or Inlet...

Page 12: ...ter pressure at the conditioner is not less than 40psi 280kPa You may elevate an additional 2ft 61cm for each additional 10psi 70kPa of water pressure When the drain line is elevated and empties into...

Page 13: ...ve s into the not in bypass position Open the water supply valve very slowly to approximately the 1 4 open position Caution If the water supply valve is opened too rapidly or too far resin may be lost...

Page 14: ...ndicator knob counterclockwise to START Figure 8 It will take a few minutes for regen eration to begin The normal regeneration schedule will not be disrupted Manual Regeneration Electricity is used on...

Page 15: ...timer assembly for servicing 1 Unplug the power cord 2 Remove the rear cover by pushing back on the tab provided on the cover with your thumb Figure 10 Next lift the cover off the valve 3 To remove th...

Page 16: ...camshaft Slide the camshaft into the timer It may be necessary to rock the timer slightly to key the camshaft into the timer When the camshaft is slid into place lift he back of the camshaft up while...

Page 17: ...teps to clean the injector screen and injector 1 Unplug the power cord 2 Shut off the water supply or put the bypass valve s into the bypass position and remove the rear cover Figure 10 3 Relieve syst...

Page 18: ...Pressure 300 psi 2069kPa Working Pressure 20 to 127 psi 138 to 876 kPa 100 psi max in Canada Voltage 24V 50 Hz 24V 60 Hz 100V 50 Hz 100V 60 Hz 230V 50 Hz 115V 60 Hz Current 50 mA Operating Temperature...

Page 19: ...1 2 in NPT male drain Valve Module Tank Adaptor Optional Bypass Valve Reinforced NORYL Inlet Outlet Manifold Brass or reinforced NORYL Rubber Parts Compounded for cold water service Injector size A W...

Page 20: ...AST0715 940 Page 20 Control Valving Identification Valve Disc Operation...

Page 21: ...AST0715 940 Page 21 Flow Diagrams...

Page 22: ...AST0715 940 Page 22...

Page 23: ...1000904 Adj Backwash Extra Salt Long Rinse Long Cycle 1000905 3 Cycle Adj Backwash 11 Motor Option 1 1000802 24V 50 Hz 1000803 24V 60 Hz 1000804 110V 50 Hz 1000805 100V 60 Hz 1000806 230V 50 Hz 10008...

Page 24: ...AST0715 940 Page 24...

Page 25: ...AST0715 940 Page 25 Valve Body and Tank Adaptor Module...

Page 26: ...No 14 for 14 in Diameter Tank 7 1030502 Ball Flow Control 1 8 Injector Assy With O rings 1 1032970 A Injector White 1032971 B Injector Blue 1032972 C Injector Red 9 Injector Cap With O rings 1 1000217...

Page 27: ...tic Pipe Adaptor Kit 1 1001605 1 in BSPT Plastic Pipe Adaptor Kit 1 1001611 3 4 in BSPT Brass Pipe Adaptor Kit 1 1001610 1 in NPT Brass Pipe Adaptor Kit 1 1001612 1 in BSPT Brass Pipe Adaptor Kit 1 Co...

Page 28: ...Restricted drain line c Injector plugged d Defective injector e Valve disc 2 and or 3 not closed f Air check prematurely closed a Water pressure must be 20 psi minimum b Remove restriction c Clean in...

Page 29: ...AST0715 940 Page 29...

Page 30: ...n be used directly without dissolving before application The recommended dosage for Calcium Hypochlorite is two grains approx 0 1 ounce per cubic foot Complete the following steps to disinfect the con...