background image

120-241E1

|

1

 

Note

If converting from natural gas to propane, order the propane conversion parts kit (IBC Part # P-802) 
from your authorized IBC distributor.

Use the natural gas conversion parts kit if the fuel source at the site uses natural gas and the modulating 
tankless water heater has been set up  to operate with propane. Check the rating plate on the tankless water 
heater to see which fuel source the particular appliance has been set up with.

Using this conversion kit, a qualified technician will need to:

 1.  Perform a fuel conversion.

 2.  Perform a combustion test.

 3.  Fill in the information required on the fuel conversion labels, and affix them to the appliance after the 

conversion is completed.

Warning

Disconnect power supply before any wiring/service is performed. Failure to do so could 
result in damage to appliance and/or electric shock.This conversion kit shall be installed by 
a qualified service agency in accordance with the manufacturer’s instructions and all 
applicable codes and requirements of the authority having jurisdiction. If the information in 
these instructions is not followed exactly, a fire, an explosion or production of carbon 
monoxide may result causing property damage, personal injury or loss of life.

 

The qualified service agency is responsible for the proper installation of this kit. The 
installation is not proper and complete until the operation of the converted appliance is 
checked as specified in the manufacturer’s instructions supplied with the kit.

The appliance will automatically de-rate the maximum input at a rate of approximately 2% per 1,000’ above 
4,500’. The gas valve's zero-governor will ensure that the gas-air mixture is not affected at altitude.

Included with the conversion kit:

Fuel Conversion Kit,  LP to NG - Superflow SFT 199 

Part #

Description

Quantity

180-173

NG orifice # 660

1

150-175 

Orifice  O-ring 19 x 2              

1

080-224 

Rating plate overlay 

1

080-107

Gas valve conversion label 

1

080-245

Installer Identification label   

1

SFT 199  - Fuel Conversion to Natural Gas 

(LP to NG) - P-803

Reviews: