© 2002 IBICO
Operations Manual
Page 5-6
Patriot 12HR, 25HC, 38HC
5.3 Feed table
To remove
1.
Lift the safety shield to its full upright position.
2.
Slide the feed table interlock latch to the right.
3.
Lift the rear of the table (the rounded side) upwards
and away from the laminator.
To replace
1.
Set the front of the feed table (the side that is not
rounded) into the table brackets first.
2.
Lower the rear of the feed table onto the table support
bar.
3.
Slide the table interlock latch to the left.
4.
Lower the safety shield to its fully closed position.
5.4 Supply shaft
To remove
1.
Slide the upper shaft to the right from the front operating
position.
2.
While pushing in on the supply shaft to the right, remove
the left side of the shaft from the brake assembly.
3.
Raise the safety shield and remove the table and repeat
the steps above for the lower supply shaft.
To replace
1.
Align the rounded end of the supply shaft into the supply
shaft hole located on the right side of the laminator from
the front operating position.
2.
Push the supply shaft in while aligning the hex end of
the supply shaft with the brake assembly.