Server driver installation in new NetWare 3.12 Server
Changes from the usual NetWare installation are necessary because this driver is
written to a new specification level that requires new NetWare loadable modules
(NLMs). The installation program is not aware of this, though, and these NLMs must
be loaded during installation of the server device driver and after the server
installation.
1. Create a diskette containing the extracted files from the NETWAREP.EXE
package file on the adapter CD-ROM.
2. Refer to Novell’s
Installation and Upgrade
manual for installation instructions.
Follow the procedure for the installation of Novell NetWare 3.12 until the
section titled “Load LAN Drivers” is next.
3. Insert the diskette that you created in step 1 into drive A. Enter the following
commands at the server prompt:
LOAD A:\NOVELL\NETWARE\NBI31X.NLM
LOAD A:\NOVELL\NETWARE\MSM31X.NLM
LOAD A:\NOVELL\NETWARE\TOKENTSM.NLM
Note:
A message referring to
protected-mode BIOS access
might appear
before installation of Novell patches. It is for information only, and can
be ignored.
4. Load the server device driver. Enter the following command at the server
prompt:
LOAD X:\NOVELL\NETWARE\IBMTRPO.LAN DATARATE=M16
It is recommended for servers that the DataRate be set to M16 or M4, and
clients be set to Auto.
Note:
See “Appendix D. Novell NetWare Server driver parameters” on page 65
for a complete list of parameters that can be specified in the
LOAD
IBMTRPO
command in the AUTOEXEC.NCF file.
5. Follow the instructions in the Novell manual, beginning with “Bind the Protocol
to the LAN Driver” and continue until you are in the file server STARTUP.NCF
file panel.
6. In addition to the instructions in the Novell manual, add the following line to
STARTUP.NCF:
Set Minimum Packet Receive Buffers = 48
Note:
Increase the minimum packet receive buffers by 48 for each additional
adapter that is installed.
7. Perform the instructions in “Create an AUTOEXEC.NCF file” in the Novell
manual. Add the following lines to the AUTOEXEC.NCF file immediately after
the
IPX INTERNAL NET
statement (replace
C:\SERVER.312\
with the location of
the NetWare Server program):
LOAD C:\SERVER.312\NBI31X.NLM
LOAD C:\SERVER.312\MSM31X.NLM
LOAD C:\SERVER.312\TOKENTSM.NLM
LOAD C:\SERVER.312\IBMTRPO.LAN NAME=IBMLS1 DATARATE=M16
BIND IPX TO IBMLS1 NET=<unique net number>
Make sure that the line containing IBMTRPO.LAN has the complete path
name.
10
IBM 16/4 Token-Ring PCI Management Adapter
Summary of Contents for 16/4 Token-Ring
Page 1: ...16 4 Token Ring PCI Management Adapter User s Guide ...
Page 6: ...vi IBM 16 4 Token Ring PCI Management Adapter ...
Page 12: ...4 IBM 16 4 Token Ring PCI Management Adapter ...
Page 44: ...36 IBM 16 4 Token Ring PCI Management Adapter ...
Page 56: ...48 IBM 16 4 Token Ring PCI Management Adapter ...
Page 60: ...52 IBM 16 4 Token Ring PCI Management Adapter ...
Page 78: ...70 IBM 16 4 Token Ring PCI Management Adapter ...
Page 84: ...76 IBM 16 4 Token Ring PCI Management Adapter ...
Page 104: ...96 IBM 16 4 Token Ring PCI Management Adapter ...