LA10049
The configuration parameter
xx
was specified incorrectly. Its default value will be used.
Explanation:
An invalid value was specified for a configuration parameter in the PROTOCOL.INI file. A default value
has been substituted.
User Action:
Change the PROTOCOL.INI file to specify a valid value for the configuration parameter that is in error.
Refer to the installation manual that came with the adapter for more information on the allowable settings for this
particular parameter.
The device driver has proceeded with its initialization using a predetermined default value for this parameter.
LA10050
The NDIS 2.0 device driver was not able to register with the Protocol Manager.
Explanation:
An unexpected error occurred when the program attempted to register a adapter with the Protocol
Manager.
User Action:
Check the drive and directory to ensure that the Protocol Manager is located in the path specified in
the CONFIG.SYS file. If this error persists, consider reinstalling the NDIS 2.0 network support software.
LA10051
The configuration parameter values have forced the internal data blocks to exceed the allowed
limit.
Explanation:
The combination of configuration parameters being used requires more than the 64-KB memory area
that is available for this adapter instance to hold its internal control information.
User Action:
Lower the value of the MaxTransmits or MinRcvBuffs parameters in the PROTOCOL.INI file to reduce
the amount of control block storage required by the device driver. Shut down and restart the computer to activate this
configuration change.
LA10053E (DOS Only)
Device Driver could not initialize. Failure code:
xx
Explanation:
The device driver was not able to initialize itself. This is most often caused by conflicts between the
device driver and other resources in the system.
User Action:
Record this message number and the failure code and contact your support personnel for assistance.
LA10054E (DOS Only)
No adapters supported by %1 were found or adapters were not correctly configured by the
machine and its BIOS.
Explanation:
The device driver was not able to find any adapters that it knows about. Either the adapter is not
installed in the computer, the adapter is malfunctioning, or the system BIOS has not correctly configured the adapter.
User Action:
Record this message number and contact your support personnel for assistance.
LA10055E (DOS Only)
No adapters initialized correctly.
xx
adapters were found in the machine.
Explanation:
The device driver was able to find the stated number of adapters. However, none of the adapters were
successfully initialized. This message is often displayed along with one or more other messages from the device
driver.
User Action:
Record this message number as well as any other messages from the device drivers along with any
specific failure codes in the messages and contact your support personnel for assistance.
64
IBM 16/4 Token-Ring PCI Management Adapter
Summary of Contents for 16/4 Token-Ring
Page 1: ...16 4 Token Ring PCI Management Adapter User s Guide ...
Page 6: ...vi IBM 16 4 Token Ring PCI Management Adapter ...
Page 12: ...4 IBM 16 4 Token Ring PCI Management Adapter ...
Page 44: ...36 IBM 16 4 Token Ring PCI Management Adapter ...
Page 56: ...48 IBM 16 4 Token Ring PCI Management Adapter ...
Page 60: ...52 IBM 16 4 Token Ring PCI Management Adapter ...
Page 78: ...70 IBM 16 4 Token Ring PCI Management Adapter ...
Page 84: ...76 IBM 16 4 Token Ring PCI Management Adapter ...
Page 104: ...96 IBM 16 4 Token Ring PCI Management Adapter ...