automatically
adjusts
the
voltage
range
setting.
Take
no
action
for
this
alarm
condition
unless
it
persists
for
more
than
five
minutes
after
a
SAN
Volume
Controller
2145-4F2
has
been
connected
to
this
2145
UPS
and
powered
on.
11.
Repeat
all
of
these
steps
to
install
additional
2145
UPSs.
Installing
the
SAN
Volume
Controller
2145-4F2
There
are
several
steps
that
you
must
perform
to
install
the
SAN
Volume
Controller
2145-4F2
node.
Installing
the
SAN
Volume
Controller
2145-4F2
consists
of
the
following
tasks:
1.
Installing
the
support
rails
in
the
rack
cabinet.
2.
Installing
the
SAN
Volume
Controller
2145-4F2.
3.
Connecting
the
SAN
Volume
Controller
2145-4F2
to
the
2145
UPS-1U
or
the
2145
UPS.
Installing
the
support
rails
for
the
SAN
Volume
Controller
2145-4F2
You
must
install
the
support
rails
that
hold
the
SAN
Volume
Controller
2145-4F2.
When
you
are
ready
to
install
the
support
rails,
perform
the
following
tasks:
v
Refer
to
the
Hardware
Location
Chart
to
determine
where
the
SAN
Volume
Controller
2145-4F2
is
to
be
installed
in
the
rack.
v
Refer
to
the
Electronic
Industries
Alliance
(EIA)
markings
on
the
rack
and
decide
where
you
are
going
to
install
the
support
rails.
Perform
the
following
steps
to
install
the
support
rails:
1.
Check
the
labels
on
the
support
rails.
Each
rail
has
a
label
that
indicates
which
is
the
front
end
of
the
rail
and
whether
the
rail
is
for
the
left
or
right
side
of
the
rack.
Perform
this
procedure
for
both
rails.
2.
Put
your
index
finger
against
the
side
of
the
latch-lever,
1
in
and
put
your
thumb
against
the
front
of
the
latch-lock
2
.
1
Latch-lever
2
Latch-lock
1
2
Figure
91.
Retracting
the
latch
lock
carrier
Appendix
B.
SAN
Volume
Controller
2145-4F2
129
Summary of Contents for 2145UPS-1U
Page 2: ......
Page 8: ...vi IBM System Storage SAN Volume Controller Hardware Installation Guide...
Page 56: ...18 IBM System Storage SAN Volume Controller Hardware Installation Guide...
Page 72: ...34 IBM System Storage SAN Volume Controller Hardware Installation Guide...
Page 102: ...64 IBM System Storage SAN Volume Controller Hardware Installation Guide...
Page 138: ...100 IBM System Storage SAN Volume Controller Hardware Installation Guide...
Page 190: ...152 IBM System Storage SAN Volume Controller Hardware Installation Guide...
Page 192: ...154 IBM System Storage SAN Volume Controller Hardware Installation Guide...
Page 200: ...162 IBM System Storage SAN Volume Controller Hardware Installation Guide...
Page 228: ...190 IBM System Storage SAN Volume Controller Hardware Installation Guide...
Page 231: ......
Page 232: ...Part Number 31P1046 Printed in USA GC27 2132 01 1P P N 31P1046...