buttons
within
60
seconds,
the
menu
changes
to
display
the
charging
progress.
You
can
switch
the
front
panel
display
to
the
menu
at
any
time
by
pressing
the
select
button
again.
5.
Press
and
release
the
up
or
down
button
until
the
Node:
option
is
displayed
on
the
first
line
of
the
front-panel
display.
6.
Verify
that
the
node
number
that
is
displayed
on
the
second
line
of
the
front-panel
display
is
the
same
as
the
node
number
that
is
printed
on
the
front
panel
of
the
node.
shows
how
the
node
number
appears
on
the
front
panel.
7.
Press
and
release
the
up
or
down
button
until
the
Ethernet
option
is
shown
on
the
front
panel
display.
The
second
line
of
the
front-panel
display
in
shows
the
message
Inactive
.
This
message
indicates
that,
although
an
Ethernet
connection
is
available,
it
cannot
yet
be
used.
8.
Press
and
release
the
up
or
down
button
until
the
FC
Port-1
option
shows
in
the
display.
9.
Check
whether
the
second
line
of
the
front-panel
display
shows
the
message
Active
.
If
Active
is
not
shown
on
the
second
line,
go
to
“MAP
5600:
Fibre
channel”
in
the
IBM
System
Storage
SAN
Volume
Controller:
Service
Guide
to
repair
the
fault.
10.
If
you
are
installing
a
SAN
Volume
Controller
2145-8F2,
go
to
step
If
you
are
installing
a
SAN
Volume
Controller
2145-8F4,
go
to
step
11.
Press
and
hold
the
down
button.
12.
Press
and
release
the
select
button.
13.
Release
the
down
button.
The
operational
speed
of
the
fibre-channel
link
is
displayed.
Use
the
cable
connection
table
that
is
provided
by
the
customer
to
verify
that
the
fibre-channel
link
is
operating
at
the
expected
speed.
If
the
operational
speed
does
not
match
the
expected
speed,
go
to
“MAP
5600:
Fibre
channel”
in
the
IBM
System
Storage
SAN
Volume
Controller:
Service
Guide
to
repair
the
fault.
14.
Press
the
select
button
to
return
to
the
fibre-channel
status
display.
15.
Press
the
right
button
to
display
each
port
in
turn
and
repeat
the
above
speed
check.
Go
to
step
16.
Press
and
release
the
left
or
right
button
to
display
the
other
port
options.
Check
whether
for
each
port,
the
second
line
of
the
front-panel
display
shows
the
message
Active
.
If
Active
is
not
shown
for
any
port,
go
to
“MAP
5600:
Fibre
channel”
in
the
IBM
System
Storage
SAN
Volume
Controller:
Service
Guide
to
repair
the
fault.
N o d e :
x x x x x x
Figure
71.
Node
number
E t h e r n e t :
I n a c t i v e
Figure
72.
Ethernet
mode
Appendix
A.
SAN
Volume
Controller
2145-8F4
and
SAN
Volume
Controller
2145-8F2
97
Summary of Contents for 2145UPS-1U
Page 2: ......
Page 8: ...vi IBM System Storage SAN Volume Controller Hardware Installation Guide...
Page 56: ...18 IBM System Storage SAN Volume Controller Hardware Installation Guide...
Page 72: ...34 IBM System Storage SAN Volume Controller Hardware Installation Guide...
Page 102: ...64 IBM System Storage SAN Volume Controller Hardware Installation Guide...
Page 138: ...100 IBM System Storage SAN Volume Controller Hardware Installation Guide...
Page 190: ...152 IBM System Storage SAN Volume Controller Hardware Installation Guide...
Page 192: ...154 IBM System Storage SAN Volume Controller Hardware Installation Guide...
Page 200: ...162 IBM System Storage SAN Volume Controller Hardware Installation Guide...
Page 228: ...190 IBM System Storage SAN Volume Controller Hardware Installation Guide...
Page 231: ......
Page 232: ...Part Number 31P1046 Printed in USA GC27 2132 01 1P P N 31P1046...