6
Site
wiring
fault
indicators
7
Battery
service
indicator
8
Battery
mode
indicator
9
General
alarm
indicator
Mode
indicator
The
mode
indicator
provides
status
information
on
the
2145
uninterruptible
power
supply
(2145
UPS)
and
is
located
on
the
front
panel.
When
the
mode
indicator
is
a
steady
green,
the
2145
UPS
is
in
normal
mode.
The
2145
UPS
checks
and
charges
its
battery
as
necessary.
When
the
mode
indicator
is
flashing
green,
the
2145
UPS
is
in
standby
mode.
Standby
mode
means
that
the
2145
UPS
is
turned
off
but
is
still
connected
to
the
main
power
source.
No
power
is
available
from
the
2145
UPS
output
sockets
but
the
2145
UPS
monitors
and
charges
its
battery
as
necessary.
When
the
mode
indicator
is
steady
red,
the
2145
UPS
is
in
bypass
mode
because
of
one
of
the
following
conditions:
v
The
2145
UPS
has
overheated
v
The
2145
UPS
has
an
overload
condition
of
103%
through
110%
for
30
seconds
v
The
2145
UPS
detects
a
fault
in
the
battery
or
in
the
2145
UPS
electronics
assembly
When
the
mode
indicator
is
flashing
red
and
the
alarm
is
sounding,
the
voltage
range
setting
might
not
be
correct.
When
a
SAN
Volume
Controller
2145-4F2
is
connected
to
the
2145
UPS,
the
SAN
Volume
Controller
2145-4F2
automatically
adjusts
the
voltage
range
setting.
Take
no
action
for
this
alarm
condition
unless
it
persists
for
more
than
five
minutes
after
a
SAN
Volume
Controller
2145-4F2
has
been
connected
to
a
2145
UPS
and
powered
on.
On
button
The
on
button
turns
on
the
main
power
to
the
2145
uninterruptible
power
supply
(2145
UPS).
To
turn
on
the
power,
press
and
hold
the
on
button
until
you
hear
a
beep
(approximately
one
second).
The
mode
indicator
stops
flashing
and
the
load-level
indicators
display
the
percentage
of
load
that
is
being
applied
to
the
2145
UPS.
Off
button
The
off
button
turns
off
the
main
power
to
the
2145
uninterruptible
power
supply
(2145
UPS).
Attention:
Never
use
the
off
button
unless
you
are
specifically
directed
to
in
the
instructions
that
are
provided
with
the
SAN
Volume
Controller
2145-4F2.
If
you
press
it
at
any
other
time,
you
might
lose
data
in
the
cluster
if
the
other
2145
UPS
fails.
To
turn
off
the
power,
press
and
hold
the
off
button
until
the
long
beep
stops
(approximately
five
seconds).
The
mode
indicator
starts
to
flash
and
the
2145
UPS
remains
in
standby
mode
until
you
disconnect
the
2145
UPS
from
the
main
power
outlet.
110
IBM
System
Storage
SAN
Volume
Controller:
Hardware
Installation
Guide
Summary of Contents for 2145UPS-1U
Page 2: ......
Page 8: ...vi IBM System Storage SAN Volume Controller Hardware Installation Guide...
Page 56: ...18 IBM System Storage SAN Volume Controller Hardware Installation Guide...
Page 72: ...34 IBM System Storage SAN Volume Controller Hardware Installation Guide...
Page 102: ...64 IBM System Storage SAN Volume Controller Hardware Installation Guide...
Page 138: ...100 IBM System Storage SAN Volume Controller Hardware Installation Guide...
Page 190: ...152 IBM System Storage SAN Volume Controller Hardware Installation Guide...
Page 192: ...154 IBM System Storage SAN Volume Controller Hardware Installation Guide...
Page 200: ...162 IBM System Storage SAN Volume Controller Hardware Installation Guide...
Page 228: ...190 IBM System Storage SAN Volume Controller Hardware Installation Guide...
Page 231: ......
Page 232: ...Part Number 31P1046 Printed in USA GC27 2132 01 1P P N 31P1046...