Country
or
region
Length
Connection
type
(attached
plug
designed
for
200
-
240
V
ac
input)
Part
number
United
States
of
America
(Chicago),
Canada,
Mexico
1.8
m
(6
ft)
NEMA
L6-15P
14F1549
Installing
the
SAN
Volume
Controller
2145-4F2
hardware
There
are
several
steps
that
you
must
perform
to
prepare
and
then
install
the
SAN
Volume
Controller
2145-4F2
hardware.
The
following
topics
describe
the
SAN
Volume
Controller
2145-4F2
hardware
installation
tasks
in
the
order
they
should
be
performed.
Note:
If
you
are
adding
a
new
I/O
group
to
an
existing
SAN
Volume
Controller
2145-4F2
cluster,
there
is
no
need
to
power
off
the
existing,
operating
cluster
nodes.
1.
Install
and
verify
the
redundant
ac
power
switch,
if
it
is
to
be
used
and
is
not
already
being
used
for
a
node.
2.
Install
the
UPS.
3.
Install
the
node.
4.
Connect
the
fibre-channel
and
Ethernet
cables
to
the
node.
5.
Connect
the
node
to
the
UPS.
6.
Verify
the
node.
7.
Install
and
verify
the
master
console,
unless
it
is
already
installed.
Optionally,
you
can
perform
this
step
first.
After
you
finish
these
steps,
the
hardware
installation
is
complete.
Installing
the
2145
UPS-1U
Before
you
can
use
the
SAN
Volume
Controller,
you
need
to
install
the
uninterruptible
power
supply
(UPS).
Complete
the
following
steps
to
install
the
2145
UPS-1U:
1.
Install
the
support
rails
for
the
2145
UPS-1U.
2.
Install
the
2145
UPS-1U
into
the
rack.
3.
Connect
the
2145
UPS-1U
battery.
4.
Connect
the
power
cables
to
the
2145
UPS-1U.
5.
Install
the
2145
UPS-1U
cable
retention
bracket.
Installing
the
support
rails
for
the
2145
UPS-1U
You
must
install
the
support
rails
in
the
rack
before
installing
the
2145
uninterruptible
power
supply-1U
(2145
UPS-1U).
Complete
the
following
prerequisites
before
installing
the
support
rails:
1.
Use
the
user’s
hardware
location
chart
to
determine
where
in
the
rack
that
the
2145
UPS-1U
is
to
be
installed.
114
IBM
System
Storage
SAN
Volume
Controller:
Hardware
Installation
Guide
|
|
|
|
Summary of Contents for 2145UPS-1U
Page 2: ......
Page 8: ...vi IBM System Storage SAN Volume Controller Hardware Installation Guide...
Page 56: ...18 IBM System Storage SAN Volume Controller Hardware Installation Guide...
Page 72: ...34 IBM System Storage SAN Volume Controller Hardware Installation Guide...
Page 102: ...64 IBM System Storage SAN Volume Controller Hardware Installation Guide...
Page 138: ...100 IBM System Storage SAN Volume Controller Hardware Installation Guide...
Page 190: ...152 IBM System Storage SAN Volume Controller Hardware Installation Guide...
Page 192: ...154 IBM System Storage SAN Volume Controller Hardware Installation Guide...
Page 200: ...162 IBM System Storage SAN Volume Controller Hardware Installation Guide...
Page 228: ...190 IBM System Storage SAN Volume Controller Hardware Installation Guide...
Page 231: ......
Page 232: ...Part Number 31P1046 Printed in USA GC27 2132 01 1P P N 31P1046...