4.
Place
the
other
end
of
the
signal
cable
into
any
vacant
position
on
the
top
row
of
serial
connectors
4
on
the
2145
UPS.
Attention:
Do
not
plug
any
signal
cables
into
the
bottom
row
of
signal
cable
connectors
or
the
2145
UPS
malfunctions.
The
SAN
Volume
Controller
2145-4F2
power
is
now
connected
to
the
2145
UPS.
Connecting
the
SAN
Volume
Controller
2145-4F2
to
the
SAN
and
to
the
Ethernet
network
Before
you
connect
the
SAN
Volume
Controller
2145-4F2
to
the
SAN,
you
must
connect
the
Ethernet
and
fibre-channel
cables.
Before
you
begin
this
task,
refer
to
the
user’s
cable
connection
table
to
find
out
where
to
connect
the
Ethernet
and
fibre-channel
cables.
1.
Connect
the
Ethernet
cable
to
Ethernet
port
1
5
in
Attention:
You
must
use
only
Ethernet
port
1
on
the
SAN
Volume
Controller.
The
software
is
configured
only
for
Ethernet
port
1.
2.
Connect
the
other
end
of
the
Ethernet
cable
to
the
proper
connector
on
the
Ethernet
hub
or
switch.
1
Fibre-channel
port
1
2
Fibre-channel
port
2
3
Fibre-channel
port
3
4
Fibre-channel
port
4
5
Ethernet
port
1
Attention:
When
routing
the
fibre-channel
cables,
do
not
tighten
the
cable
straps
or
bend
the
cables
to
a
radius
smaller
than
76
mm
(3
in.).
3.
Connect
the
fibre-channel
cables
to
the
fibre-channel
ports
as
required
by
the
user’s
configuration.
4.
Connect
the
other
ends
of
the
fibre-channel
cables
to
the
proper
connectors
of
the
fibre-channel
switches.
Complete
steps
through
for
each
node
that
you
need
to
connect
to
the
SAN
and
to
the
Ethernet
network.
5
2
1
3
4
svc00360
Figure
99.
Connectors
at
the
back
of
the
SAN
Volume
Controller
2145-4F2
136
IBM
System
Storage
SAN
Volume
Controller:
Hardware
Installation
Guide
Summary of Contents for 2145UPS-1U
Page 2: ......
Page 8: ...vi IBM System Storage SAN Volume Controller Hardware Installation Guide...
Page 56: ...18 IBM System Storage SAN Volume Controller Hardware Installation Guide...
Page 72: ...34 IBM System Storage SAN Volume Controller Hardware Installation Guide...
Page 102: ...64 IBM System Storage SAN Volume Controller Hardware Installation Guide...
Page 138: ...100 IBM System Storage SAN Volume Controller Hardware Installation Guide...
Page 190: ...152 IBM System Storage SAN Volume Controller Hardware Installation Guide...
Page 192: ...154 IBM System Storage SAN Volume Controller Hardware Installation Guide...
Page 200: ...162 IBM System Storage SAN Volume Controller Hardware Installation Guide...
Page 228: ...190 IBM System Storage SAN Volume Controller Hardware Installation Guide...
Page 231: ......
Page 232: ...Part Number 31P1046 Printed in USA GC27 2132 01 1P P N 31P1046...