Additional
space
requirements
Location
Additional
space
requirements
Reason
Left
and
right
sides
50
mm
(2
in.)
Cooling
air
flow
Back
Minimum:
100
mm
(4
in.)
Cable
exit
Heat
output
of
each
SAN
Volume
Controller
2145-8G4
node
Model
Heat
output
per
node
SAN
Volume
Controller
2145-8G4
400
W
(1350
Btu
per
hour)
Fibre-channel
port
numbers
and
worldwide
port
names
Fibre-channel
ports
are
identified
by
their
physical
port
number
and
by
a
worldwide
port
name
(WWPN).
The
physical
port
numbers
identify
fibre-channel
cards
and
cable
connections
when
you
perform
service
tasks.
The
WWPNs
are
used
for
tasks
such
as
fibre-channel
switch
configuration
and
to
uniquely
identify
the
devices
on
the
SAN.
The
physical
port
numbers
are
1
-
4,
counting
from
left
to
right
when
you
view
the
rear
panel
of
the
SAN
Volume
Controller.
The
WWPNs
are
derived
from
the
worldwide
node
name
(WWNN)
of
the
SAN
Volume
Controller
in
which
the
card
is
installed.
The
WWNN
is
in
the
form
50050768010
XXXXX,
where
XXXXX
is
initially
derived
from
the
unit
and
is
specific
to
a
SAN
Volume
Controller.
You
can
change
the
XXXXX
value
by
using
the
front
panel
to
facilitate
service
controller
concurrent
replacement
and
to
enable
some
concurrent
upgrade
operations.
The
WWPNs
are
in
the
form
5005076801
QXXXXX
,
where
XXXXX
is
as
previously
stated
and
Q
is
related
to
the
port
number
as
follows:
Port
Value
of
Q
1
4
2
3
3
1
4
2
SAN
Volume
Controller
2145-8G4
fibre-channel
port
numbers
and
worldwide
port
names
The
SAN
Volume
Controller
2145-8G4
fibre-channel
ports
are
identified
by
their
physical
port
number
and
by
a
worldwide
port
name
(WWPN).
16
IBM
System
Storage
SAN
Volume
Controller:
Hardware
Installation
Guide
Summary of Contents for 2145UPS-1U
Page 2: ......
Page 8: ...vi IBM System Storage SAN Volume Controller Hardware Installation Guide...
Page 56: ...18 IBM System Storage SAN Volume Controller Hardware Installation Guide...
Page 72: ...34 IBM System Storage SAN Volume Controller Hardware Installation Guide...
Page 102: ...64 IBM System Storage SAN Volume Controller Hardware Installation Guide...
Page 138: ...100 IBM System Storage SAN Volume Controller Hardware Installation Guide...
Page 190: ...152 IBM System Storage SAN Volume Controller Hardware Installation Guide...
Page 192: ...154 IBM System Storage SAN Volume Controller Hardware Installation Guide...
Page 200: ...162 IBM System Storage SAN Volume Controller Hardware Installation Guide...
Page 228: ...190 IBM System Storage SAN Volume Controller Hardware Installation Guide...
Page 231: ......
Page 232: ...Part Number 31P1046 Printed in USA GC27 2132 01 1P P N 31P1046...