1
Fibre-channel
port
1
2
Fibre-channel
port
2
3
Fibre-channel
port
3
4
Fibre-channel
port
4
5
Ethernet
port
1
Attention:
When
routing
the
fibre-channel
cables,
do
not
tighten
the
cable
straps
or
bend
the
cables
to
a
radius
smaller
than
76
mm
(3
in.).
3.
Connect
the
fibre-channel
cables
to
the
fibre-channel
ports
as
required
by
the
user’s
configuration.
4.
Connect
the
other
ends
of
the
fibre-channel
cables
to
the
proper
connectors
of
the
fibre-channel
switches.
Complete
steps
through
for
each
node
that
you
need
to
connect
to
the
SAN
and
to
the
Ethernet
network.
Verifying
the
SAN
Volume
Controller
2145-8G4
installation
You
must
verify
the
SAN
Volume
Controller
installation
after
the
installation
has
completed.
This
task
shows
you
how
to
verify
the
installation
after
you
install
the
SAN
Volume
Controller
in
the
rack
and
connect
it
to
the
uninterruptible
power
supply,
the
storage
area
network
(SAN),
and
the
Ethernet.
Note:
If
at
any
point
the
SAN
Volume
Controller
does
not
operate
as
described,
see
“MAP
5000:
Start”
in
the
IBM
System
Storage
SAN
Volume
Controller:
Service
Guide
,
unless
a
different
maintenance
analysis
procedure
(MAP)
is
specified.
Perform
the
following
steps
to
verify
installation:
1.
Press
the
SAN
Volume
Controller
power
switch.
Verify
that
the
green
power
light
is
on.
If
the
light
is
not
on,
see
“MAP
5000:
Start”
in
the
IBM
System
Storage
SAN
Volume
Controller:
Service
Guide
to
repair
the
problem.
Note:
You
do
not
need
to
install
any
software.
The
node
boots
automatically.
Verify
that
the
node
is
booting
without
error.
If
it
boots
without
error,
either
the
Charging
message
or
Cluster:
is
displayed
in
the
first
line
of
the
front-panel
display.
svc00228
1
2
3
4
5
Figure
35.
Connectors
at
the
back
of
the
SAN
Volume
Controller
2145-8G4
Chapter
6.
Installing
the
SAN
Volume
Controller
2145-8G4
hardware
59
|
|
|
Summary of Contents for 2145UPS-1U
Page 2: ......
Page 8: ...vi IBM System Storage SAN Volume Controller Hardware Installation Guide...
Page 56: ...18 IBM System Storage SAN Volume Controller Hardware Installation Guide...
Page 72: ...34 IBM System Storage SAN Volume Controller Hardware Installation Guide...
Page 102: ...64 IBM System Storage SAN Volume Controller Hardware Installation Guide...
Page 138: ...100 IBM System Storage SAN Volume Controller Hardware Installation Guide...
Page 190: ...152 IBM System Storage SAN Volume Controller Hardware Installation Guide...
Page 192: ...154 IBM System Storage SAN Volume Controller Hardware Installation Guide...
Page 200: ...162 IBM System Storage SAN Volume Controller Hardware Installation Guide...
Page 228: ...190 IBM System Storage SAN Volume Controller Hardware Installation Guide...
Page 231: ......
Page 232: ...Part Number 31P1046 Printed in USA GC27 2132 01 1P P N 31P1046...