Symptom / Error
FRU / Action in Sequence
601, 6XX
(601: Diskette drive or
controller error.)
1. Go to “Diskette Drive
Checkout” on
page 27.
2. Diskette drive
assembly.
3. Diskette.
4. System board.
602
(Diskette read error.)
1. Go to “Diskette Drive
Checkout” on
page 27.
2. Diskette.
3. Diskette drive
assembly.
604
(Unacceptable ID was read
from the diskette drive.)
1. Go to “Diskette Drive
Checkout” on
page 27.
2. Diskette drive
assembly.
3. System board.
11XX
1101: Serial_A test failure.
1. Serial device.
2. Communication cable.
3. System board.
12XX
1201: Serial_B test failure.
1. System board
(infrared).
17XX
1701: Hard disk
controller failure.
1780, 1790: Hard disk
0 error.
1781, 1791: Hard disk
1 error.
1. Hard disk drive.
2. System board.
24XX
(2401: System board video
error.)
1. System board.
808X
8081: PCMCIA
presence test failure.
(PCMCIA revision
number also checked.)
8082: PCMCIA register
test failure.
1. PC Card slot
assembly.
2. PCMCIA device.
3. System board.
860X
(Pointing device error when
TrackPoint III is disabled.)
8601: System bus
error–8042 mouse
interface.
8602: External mouse
error.
8603: System bus
error or mouse error.
1. External mouse.
2. External keyboard.
3. System board.
ThinkPad 560X (2640-60x, 70x)
39
Summary of Contents for 2640-60x
Page 2: ......
Page 8: ...vi IBM ThinkPad 560X 2640 60x 70x HMM ...
Page 10: ...viii IBM ThinkPad 560X 2640 60x 70x HMM ...
Page 28: ...18 IBM ThinkPad 560X 2640 60x 70x HMM ...
Page 72: ...1030 Battery Pack Turn the computer upside down 62 IBM ThinkPad 560X 2640 60x 70x HMM ...
Page 74: ...64 IBM ThinkPad 560X 2640 60x 70x HMM ...
Page 92: ...82 IBM ThinkPad 560X 2640 60x 70x HMM ...
Page 94: ...84 IBM ThinkPad 560X 2640 60x 70x HMM ...
Page 98: ...Parts Listing 560X 2640 60x 70x 88 IBM ThinkPad 560X 2640 60x 70x HMM ...
Page 110: ...IBM Part Number 05L1768 Printed in U S A Sð5L 1768 ðð ...