Table 3. Firmware Error Codes. (continued)
Error Code Description
Action / Possible Failing FRU
40111101 Power good signal low on either
processor card 1 or processor card 2.
If AIX is running, check the AIX error
log to find out which processor card is
failing. If AIX in not available, check
the service processor error log.
Replace the failing processor.
Location: P1-C1 or P1-C2.
40111102 Wrong processor card plugged into the
system.
1. Remove processor cards.
2. Verify FRU number of new
processor card is correct before
installation.
40111122 High PCI +5.0 voltage reading detected
1. If a location code is displayed with
this error code, replace the part at
that location.
2. Replace the power supplies
one-at-a-time.
Location: P3-V1
Location: P3-V2
Location: P3-V3
3. Replace the system board.
Location: P1
(See note 3 on page 109.)
40111132 A high PCI 3.3 voltage was detected
1. If a location code is displayed with
this error code, replace the part at
that location.
2. Replace the power supplies
one-at-a-time.
Location: P3-V1
Location: P3-V2
Location: P3-V3
3. Replace the system board.
Location: P1
(See note 3 on page 109.)
40111152 A high PCI +12 voltage was detected
1. If a location code is displayed with
this error code, replace the part at
that location.
2. Replace the power supplies
one-at-a-time.
Location: P3-V1
Location: P3-V2
Location: P3-V3
3. Replace the system board.
Location: P1
(See note 3 on page 109.)
144
Service Guide
Summary of Contents for 265
Page 1: ...IntelliStation POWER 9112 Model 265 Service Guide SA38 0609 00 IBM...
Page 2: ......
Page 3: ...IntelliStation POWER 9112 Model 265 Service Guide SA38 0609 00 IBM...
Page 14: ...xii Service Guide...
Page 20: ...Fan Locations 1 2 3 4 1 Fan 1 2 Fan 2 3 Fan 3 4 Fan 4 4 Service Guide...
Page 46: ...30 Service Guide...
Page 96: ...80 Service Guide...
Page 190: ...174 Service Guide...
Page 287: ...Replacement Replace in reverse order Chapter 9 Removal and Replacement Procedures 271...
Page 308: ...292 Service Guide...
Page 324: ...308 Service Guide...
Page 328: ...312 Service Guide...
Page 354: ...338 Service Guide...
Page 363: ......
Page 364: ...IBM Printed in U S A February 2002 SA38 0609 00...
Page 365: ...Spine information IBM IntelliStation POWER 9112 Model 265 Service Guide SA38 0609 00...