MAP 1240: Memory Problem Resolution
Note: The firmware checkpoint that sent you here could be one of the following: E122,
E213, E214, E218, E220 or E3xx. You may also have been sent here by an
8-digit error code.
Purpose of This MAP
This MAP is used to troubleshoot a problem during the memory test when the system
stops at a memory checkpoint and/or a error code is displayed on the operator panel.
Notes:
1. If the symptom changes while you are using this MAP, check for loose cards,
cables, and obvious problems. If you do not find a problem, go to “MAP 1540:
Minimum Configuration” on page 59.
2. The service processor may have recorded one or more symptoms in its error log. It
is a good idea to examine that error log before proceeding (see Service Processor
System Information Menu). If you find an obvious problem, fix the problem; then go
to
″
MAP 0410: Repair Checkout
″
in the
RS/6000
Eserver
pSeries Diagnostic
Information for Multiple Bus Systems.
3. The service processor may have been set by the user to monitor service operations
and to attempt recoveries. You might want to disable these actions while you
diagnose and service the system. If you disable them, make notes of their current
settings so that you can restore them before you leave. The following settings may
be of interest to you.
Surveillance
From the Service Processor Setup Menu, go to
the Surveillance Setup Menu and disable
surveillance.
Unattended Start
From the Service Processor System Power
Control Menu, disable unattended start mode.
Reboot Policy
From the System Power Control Menu, go to
the Reboot/Restart Policy Setup Menu and set:
1. Number of reboot attempts to 0 (zero)
2. Use OS-Defined restart policy to No
3. Enable supplemental restart policy to No.
Call Out
From the Call-In/Call-Out Setup Menu, go to
the Serial Port Selection Menu and disable
call-out on both serial ports.
Chapter 3. Maintenance Analysis Procedures (MAPs)
45
Summary of Contents for 265
Page 1: ...IntelliStation POWER 9112 Model 265 Service Guide SA38 0609 00 IBM...
Page 2: ......
Page 3: ...IntelliStation POWER 9112 Model 265 Service Guide SA38 0609 00 IBM...
Page 14: ...xii Service Guide...
Page 20: ...Fan Locations 1 2 3 4 1 Fan 1 2 Fan 2 3 Fan 3 4 Fan 4 4 Service Guide...
Page 46: ...30 Service Guide...
Page 96: ...80 Service Guide...
Page 190: ...174 Service Guide...
Page 287: ...Replacement Replace in reverse order Chapter 9 Removal and Replacement Procedures 271...
Page 308: ...292 Service Guide...
Page 324: ...308 Service Guide...
Page 328: ...312 Service Guide...
Page 354: ...338 Service Guide...
Page 363: ......
Page 364: ...IBM Printed in U S A February 2002 SA38 0609 00...
Page 365: ...Spine information IBM IntelliStation POWER 9112 Model 265 Service Guide SA38 0609 00...