background image

v

   

Communication

 

error

 

to

 

the

 

blade

 

or

 

user

 

doesn’t

 

have

 

permission

 

for

 

OFM

 

on

 

a

 

blade.

 

v

   

HBA

 

firmware

 

needs

 

to

 

be

 

upgraded

 

to

 

support

 

OFM.

Parsing

 

errors

 

This

 

table

 

contains

 

a

 

list

 

of

 

the

 

parsing

 

errors

 

that

 

can

 

be

 

generated

 

when

 

processing

 

the

 

OFM

 

configuration

 

file,

 

with

 

an

 

explanation

 

of

 

the

 

cause

 

of

 

each

 

error.

 

 

Table

 

11.

 

Parsing

 

errors

 

Error

 

message

 

Description

 

Assuming

 

boot

 

type

 

`None`

 

The

 

“Boot

 

Type”

 

field

 

has

 

been

 

left

 

empty

 

 

the

 

system

 

will

 

assume

 

a

 

value

 

of

 

“none”

 

and

 

continue

 

processing

 

the

 

line.

 

Assuming

 

mode

 

`Ignore`

 

The

 

“Mode”

 

field

 

has

 

been

 

left

 

empty

 

 

the

 

system

 

will

 

assume

 

a

 

value

 

of

 

“Ignore”

 

and

 

continue

 

processing.

 

Attempt

 

to

 

add

 

multiple

 

boot

 

targets

 

to

 

a

 

blade

 

with

 

the

 

same

 

priority

 

A

 

single

 

priority

 

value

 

for

 

a

 

target

 

can

 

only

 

be

 

used

 

once

 

for

 

a

 

given

 

slot.

 

Attempt

 

to

 

redefine

 

slot

 

There

 

are

 

multiple

 

lines

 

defining

 

a

 

slot.

 

A

 

slot

 

must

 

be

 

defined

 

before

 

it

 

is

 

used

 

and

 

cannot

 

be

 

defined

 

more

 

than

 

once.

 

Attempt

 

to

 

use

 

a

 

slot

 

that

 

has

 

not

 

yet

 

been

 

defined

 

A

 

slot

 

must

 

be

 

defined

 

before

 

it

 

used.

 

The

 

OFM

 

configuration

 

file

 

contains

 

a

 

reference

 

to

 

a

 

slot

 

that

 

has

 

not

 

been

 

defined

 

when

 

referenced.

 

Attempt

 

to

 

write

 

non-Ethernet

 

data

 

to

 

Ethernet

 

port

 

The

 

OFM

 

configuration

 

file

 

includes

 

an

 

attempt

 

to

 

define

 

a

 

non-Ethernet

 

port

 

to

 

an

 

Ethernet-only

 

port

 

number

 

(1

 

or

 

2).

 

Bad

 

boot

 

type

 

The

 

“Boot

 

type”

 

string

 

cannot

 

be

 

parsed.

 

Bad

 

entry

 

type

 

The

 

entry

 

type

 

(One

 

of:

 

BladeCenter,

 

Slot,

 

Eth,

 

FC,

 

FCTarget)

 

was

 

not

 

recognized.

 

Bad

 

IP

 

address

 

The

 

IP

 

address

 

was

 

incorrectly

 

formed

 

or,

 

in

 

the

 

case

 

of

 

a

 

hostname,

 

the

 

DNS

 

lookup

 

failed.

 

Bad

 

offset

 

number

 

Cannot

 

parse

 

the

 

offset

 

number,

 

or

 

the

 

number

 

is

 

out

 

of

 

range.

 

(Offsets

 

must

 

be

 

in

 

the

 

range

 

0-3)

 

Bad

 

port

 

number

 

Cannot

 

parse

 

the

 

port

 

number,

 

or

 

the

 

number

 

is

 

out

 

of

 

range.

 

(Ports

 

must

 

be

 

in

 

the

 

range

 

1-8

 

for

 

Ethernet

 

ports

 

or

 

3-8

 

for

 

all

 

other

 

types)

 

Bad

 

slot

 

number

 

Cannot

 

correctly

 

parse

 

the

 

slot

 

number

 

or

 

it

 

is

 

out

 

of

 

range.

 

The

 

exact

 

range

 

depends

 

on

 

the

 

BladeCenter

 

type

 

(BCH,

 

BCS,

 

BCHT),

 

but

 

is

 

never

 

less

 

than

 

1

 

or

 

more

 

than

 

14.

 

This

 

error

 

can

 

also

 

occur

 

when

 

the

 

slot

 

field

 

does

 

not

 

have

 

a

 

closing

 

comma.

 

Bad

 

target

 

priority

 

-

 

must

 

be

 

first

 

or

 

second

 

Cannot

 

parse

 

the

 

target

 

priority,

 

or

 

it

 

was

 

out

 

of

 

range

 

(first/second).

 

Targets

 

can

 

only

 

be

 

set

 

as

 

the

 

first

 

or

 

second

 

priority.

 

 

Chapter

 

6.

 

Troubleshooting

 

35

Summary of Contents for 26R0881

Page 1: ...IBM Systems IBM BladeCenter Open Fabric Manager Installation and User s Guide Version 2 1...

Page 2: ......

Page 3: ...IBM Systems IBM BladeCenter Open Fabric Manager Installation and User s Guide Version 2 1...

Page 4: ...sion 2 1 of IBM BladeCenter Open Fabric Manager and to all subsequent releases and modifications until otherwise indicated in new editions Copyright International Business Machines Corporation 2007 20...

Page 5: ...iguration 20 Viewing the configuration in a local chassis 20 Retrieving the current configuration 21 Chapter 5 Using OFM and OFM Advanced upgrade 23 Using OFM 23 Initial deployment 23 Adding a new cha...

Page 6: ...iv IBM BladeCenter Open Fabric Manager Installation and User s Guide...

Page 7: ...Ethernet switches that support OFM 4 6 Pass thru modules and switches that support OFM 5 7 Supported software OFM Advanced upgrade 6 8 BladeScanner and ChassisUpdate log file locations 8 9 Blade addr...

Page 8: ...vi IBM BladeCenter Open Fabric Manager Installation and User s Guide...

Page 9: ...ser s guide This user s guide is for system administrators and operators using OFM from IBM Director or the Advanced Management Module AMM to replace and recover blades in their environment Copyright...

Page 10: ...viii IBM BladeCenter Open Fabric Manager Installation and User s Guide...

Page 11: ...dance or advice Important These notices provide information or advice that might help you avoid inconvenient or difficult situations CAUTION These notices indicate possible damage to programs devices...

Page 12: ...x IBM BladeCenter Open Fabric Manager Installation and User s Guide...

Page 13: ...ent module Web interface you can create addresses for blade servers save the addresses to a configuration file deploy the addresses to the blade slots in the same chassis or in up to 100 different cha...

Page 14: ...Important OFM is a prerequisite of OFM Advanced upgrade 2 IBM BladeCenter Open Fabric Manager Installation and User s Guide...

Page 15: ...h for IBM BladeCenter 39Y9306 1 43 or later v1 46 or later Emulex 4Gb SFF Fibre Channel Expansion Card 39Y9186 6 02a2 or later 6 02a7 or later Emulex 4Gb Fibre Channel Expansion Card CFFv for IBM Blad...

Page 16: ...5601 Any version Brocade Enterprise SAN Switch Module for IBM BladeCenter 90P0165 Any version Brocade 10 port SAN Switch Module for IBM eServer BladeCenter 32R1813 Any version Brocade 20 port SAN Swit...

Page 17: ...or IBM BladeCenter 32R1861 Any version Nortel Layer 2 7 Gigabit Ethernet Switch Module for IBM BladeCenter 32R1859 Any version Nortel Networks TM Layer 2 7 Gigabit Ethernet Switch Module for IBM eServ...

Page 18: ...first update the firmware of the BladeCenter and blades including BMC BIOS and additional expansion cards in your environment For a list of the latest firmware see Software and device drivers IBM Bla...

Page 19: ...n access from the administrative console Note Do not unzip the firmware update package in the BladeCenterUpdates directory Each firmware update package includes a readme file If you unzip the package...

Page 20: ...the parameter from the response file and updates the applicable systems BladeScanner and ChassisUpdate record the transactions that they perform in a single log file The log file is created in the fo...

Page 21: ...HBA firmware updates 2 Create a bootable DOS diskette image containing the doslpcfg exe flash tool and the flash image name prg flash file 3 Boot the blade to the downloaded image by either creating...

Page 22: ...with the Standalone Diagnostics CD ROM to download firmware to the Emulex or QLogic HBA After starting the Standalone Diagnostics CD ROM the Diagnostics CD must be removed and replaced with the CD you...

Page 23: ...ector console machines Installing the IBM Director extension version of OFM Advanced upgrade for Windows Follow these steps to install the IBM Director extension version of OFM Advanced upgrade for Wi...

Page 24: ...dvanced upgrade for Linux Make sure that IBM Director 5 20 2 is installed and running on the server Specifically check that the IBM Director Server services are running For IBM Director download infor...

Page 25: ...wnload 46C3551GMAR iso 2 Mount the iso image to a mount point and directory mkdir mnt iso mount 46C3551GMAR iso mnt iso t iso9660 cd mnt iso 3 Run the script file BOFMAUxx_StandAlone_Linux sh 4 Instal...

Page 26: ...14 IBM BladeCenter Open Fabric Manager Installation and User s Guide...

Page 27: ...te Another option for Vendor is User Defined 4 For the FC Address Type use the pull down under Vendor and select Emulex or QLogic 5 Click Advanced option and check the box next to Generate an FC targe...

Page 28: ...a vendor automatically sets values within that range You can also set it to user defined mode and select any range by editing the From and To fields The default address ranges are as follows Emulex WW...

Page 29: ...the NetXen 10 Gb Ethernet Expansion Card for IBM BladeCenter 39Y9271 do not use the Advanced option button to apply Fibre Channel addresses to ports This will generate errors v Using the Advanced opt...

Page 30: ...M configuration to the blades the AMM disables the OFM configuration on all the blades that are about to be re configured As a result there can be no address duplication even if the operation has not...

Page 31: ...on File Has Been Created page click creating a requirements report Creating a requirements report from the main Open Fabric Manager Configuration Management page on the AMM Web interface 1 Login to th...

Page 32: ...ter you locate your configuration file and select advanced options click OK The AMM will start to prepare for applying the new OFM configuration and any errors that occur during this process will be r...

Page 33: ...ons of device address type Ethernet FC or FC target In addition this page displays information about whether devices attached to this slot support OFM and if any address type and value was consumed by...

Page 34: ...onfiguration file automatically on page 15 5 Click Retrieve The AMM will start to retrieve the information On completion your browser will launch the File Save window allowing you to save the generate...

Page 35: ...pply the OFM configuration See Applying a new configuration on page 20 Adding a new chassis to the domain When you need to add a new chassis to the domain you will need to add its OFM configuration to...

Page 36: ...n the chassis the OFM configuration is cleared If the current AMM is functioning the best approach is to insert the new AMM in the second slot as a standby AMM for a few minutes This allows the primar...

Page 37: ...M Director discover a chassis automatically or you can manually add a chassis to the IBM Director Console interface Follow these steps to perform chassis discovery Discovering a chassis automatically...

Page 38: ...en to ensure that there will be no address duplications in any of the profiles 8 To assign Ethernet MAC addresses to slots click the Automatically Assign Addresses check box next to the Ethernet MAC a...

Page 39: ...e you will need to select a chassis and a blade then edit the address settings The following steps will guide you through this process a Select a chassis in the Select Chassis box by clicking on the I...

Page 40: ...Address Configuration Profile Select a chassis 3 A Blade Address Configuration chassis name window will launch Click Execute now to create a schedule job for this task or execute immediately 4 Wait f...

Page 41: ...rt based VLANs are migrated from the active blade to the standby blade The software will connect to all of the Ethernet Switches in the active blade s chassis and read the VLAN port information associ...

Page 42: ...failover is in use Creating an event action plan Refer to the IBM Director documentation for instructions to create event action plans For detailed instructions see Managing event action plans http p...

Page 43: ...and application problems Problem Solution No blades show up in the available blades section Make sure that the blades and the BladeCenter chassis have been completely detected Only the blades from on...

Page 44: ...er Click on the name of the blade Verify that the OFM configuration is enabled Verify that the blade supports OFM Verify that the blade system management processor supports OFM If not then upgrade the...

Page 45: ...option to provide an alternate user name and password for the chassis If you check the box next to use this user and password for the rest of the AMMs this user name and password will be attempted on...

Page 46: ...e OFM configuration for the slots that are about to be re configured If there is a failure disabling the OFM configuration for any of the blades the Web interface displays an Open Fabric Manager Confi...

Page 47: ...uration file contains a reference to a slot that has not been defined when referenced Attempt to write non Ethernet data to Ethernet port The OFM configuration file includes an attempt to define a non...

Page 48: ...is required Invalid integer Cannot parse an integer number mac or wwnn field is too short or too long Too few or too many bytes in an EUI field Maximum value is 0xfffffffe for longer values use EUI no...

Page 49: ...he forum for IBM Director installations on all supported operating systems and hardware Although participating in the customer forum does not guarantee an answer from an IBM representative the forum c...

Page 50: ...tion for instructions for using the diagnostic programs The troubleshooting information or the diagnostic programs might tell you that you need additional or updated device drivers or other software I...

Page 51: ...BladeCenter and x86 based system information Before you contact IBM for assistance or append to the customer forum you should gather the following information for the affected systems Note Frequently...

Page 52: ...ges that occur v The version of IBM Director that is installed Also note whether it is a new installation or an upgrade installation If it is an upgrade installation note from which version of IBM Dir...

Page 53: ...or electronic assistance with usage configuration and software problems with System p servers Fixes and updates are part of the warranty of the SWMA product and are included in your license for this p...

Page 54: ...hnical Support ETS which is a proactive support option to Support Line for non IBM x86 systems For information about which products are supported by Support Line in your country or region go to www 93...

Page 55: ...in the original structure as much as possible in order to retain the readability of the file For certain purposes it might be appropriate to extract a smaller section of the domain into a new file so...

Page 56: ...for the ordering of the file The BladeCenter section should always come before slots belonging to it and only one BladeCenter section can exist for a particular BladeCenter If no BladeCenter section e...

Page 57: ...given the system creates one based on the IP address Restriction Quotes are not allowed Commas can only be included if the string is quoted Port section There are currently three types of port entrie...

Page 58: ...the OS level MAC2 optional This is the secondary MAC address for those Ethernet cards that support this option If you do not supply a value for this field it is not applied VLAN2 optional This is the...

Page 59: ...et LUN required This is the LUN of the target For numbers less than four bytes long this can be specified as a decimal or hexadecimal number where hexadecimal numbers are preceded by 0x For longer num...

Page 60: ...vices on the blade is as follows v Ports 1 and 2 are reserved for the on board Ethernet devices v Ports 3 and 4 are reserved for standard expansion cards v Ports 5 to 8 are reserved for high speed exp...

Page 61: ...For detailed information related to the AMM Web interface see the IBM BladeCenter Management Module User s Guide ftp ftp software ibm com systems support system_x_pdf 44r5274 pdf Accessibility Accessi...

Page 62: ...would cause inconsistencies with the configuration of other chassis The OFM configuration is chassis based and will not transfer with the physical AMM When an AMM is moved to a new chassis it clears...

Page 63: ...for that slot 2 If a slot has OFM configuration enabled and the system management processor of the blade in that slot does not support OFM then a warning event is generated 3 If a slot has OFM configu...

Page 64: ...52 IBM BladeCenter Open Fabric Manager Installation and User s Guide...

Page 65: ...rector 5 10 Update 2 5 10 2 IBM Director 5 10 Update 1 5 10 1 IBM Director 5 10 IBM Director 4 22 IBM Director 4 22 Upward Integration Modules UIMs IBM Director 4 21 IBM Director 4 20 v IBM Director H...

Page 66: ...as Remote Deployment Manager Capacity Manager Systems Availability and Software Distribution Premium Edition for the following IBM products v IBM BladeCenter v IBM System i v IBM System p v IBM Syste...

Page 67: ...byte DBCS information contact the IBM Intellectual Property Department in your country or send inquiries in writing to IBM World Trade Asia Corporation Licensing 2 31 Roppongi 3 chome Minato ku Tokyo...

Page 68: ...ds and products All of these names are fictitious and any similarity to the names and addresses used by an actual business enterprise is entirely coincidental Information concerning non IBM products w...

Page 69: ...ed trademark of Linus Torvalds in the United States other countries or both Microsoft and Windows are registered trademarks of Microsoft Corporation in the United States other countries or both Other...

Page 70: ...58 IBM BladeCenter Open Fabric Manager Installation and User s Guide...

Page 71: ...metric multiprocessors SMP BladeCenter chassis A BladeCenter unit that acts as an enclosure It enables the individual blade servers to share resources such as the management switch power and blower mo...

Page 72: ...uter on which IBM Director Console is installed management module The BladeCenter component that handles system management functions It configures the chassis and switch modules communicates with the...

Page 73: ...e channel 3 network 3 passthru 3 requirements 3 I IBM technical support center information to provide 39 incorrect OFM address usage troubleshooting OFM address usage 32 initial deployment 23 installi...

Page 74: ...M firmware 6 updating AMM firmware using BladeScanner 7 updating AMM firmware using ChassisUpdate 7 updating AMM firmware using UXBC 7 updating blade BIOS 9 updating blade BMC firmware 8 updating Emul...

Page 75: ...ation about products and prices please contact your IBM branch office your IBM business partner or your authorized remarketer When you send comments to IBM you grant IBM a nonexclusive right to use or...

Page 76: ...x 12195 Research Triangle Park NC 27709 9990 _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _...

Page 77: ......

Page 78: ...Part Number xxxxxxx Printed in USA 1P P N xxxxxxx...

Reviews: