Part
number
Units
per
assembly
Description
11P4861
1
Blank
cassette
11P3990
1
Door
key
44P0182
1
DASD
service
tool
11P4914
1
MCM/L3/Pass-through
plug
location
map
(tri-fold
chart):
should
be
installed
in
the
primary
rack.
11P4055
N/A
Plug
count
adhesive
replacement
label
44P209
1
Test
card
assembly
MCM/L3
short-to-GND
00P7023
36P2435
36P2436
36P2437
N/A
N/A
Vacuum
cleaner
(110
Vac)
Vacuum
cleaner
(220
Vac)
Omega
Filter
0.3
Micron
Cord
Omega
UK
Plug
07H6824
12
Bracket,
insert
07H6823
2
Bracket,
11
x
6
insert
11P1262
4
Bracket,
assembly
with
foam
07H6827
4
Blank
filler
plate
-
3
07H2826
3
Blank
filler
plate
-
1
54G2882
16
Screws
31L7174
1
Velcro
(roll)
08J5557
1
Wheel
chocks
44P0144
Tailgate
assembly
09P2481
Rack
lift
tool
11P4369
Lift
place
assembly
tool
Models
870
and
890
-
Shorts
test
qualified
service
meters
and
fail
criteria:
For
use
by
authorized
service
providers.
Use
the
table
below
to
help
you
choose
a
meter
to
use
when
performing
the
MCM
or
L3
shorts
test.
Table
1.
Shorts
test
qualified
service
meters
and
fail
criteria
Manufacturer
Model
Range
(ohm)
Accuracy
at
1.0
ohm
or
less
Fail
criteria
(ohm)
Fluke
8060A
200
+/-0.04
+0.40
Fluke
8060A/AA
200
+/-0.04
+0.40
Fluke
8062A
200
+/-0.04
+0.40
Fluke
187
500
+/-0.10
+0.40
Fluke
189
500
+/-0.10
+0.40
Fluke
83
(original
models)
400
+/-0.10
+0.40
Fluke
85
(original
models)
400
+/-0.10
+0.40
Fluke
87
(original
models)
400
+/-0.10
+0.40
Fluke
87-4
500
+/-0.10
+0.40
Fluke
89-4
500
+/-0.10
+0.40
122
Hardware
(Remove
and
Replace;
Part
Locations
and
Listings)
Summary of Contents for 270
Page 2: ......
Page 12: ...x Hardware Remove and Replace Part Locations and Listings...
Page 279: ...Figure 3 CCIN 2881 with pluggable DIMM Analyze hardware problems 267...
Page 281: ...Figure 6 Models 830 SB2 with FC 9074 HSL and SPCN locations Analyze hardware problems 269...
Page 283: ...Figure 1b Model 840 SB3 processor tower dual line cord Analyze hardware problems 271...
Page 294: ...01 gif port and LED locations 282 Hardware Remove and Replace Part Locations and Listings...
Page 295: ...s src rzaq4519 gif locations Analyze hardware problems 283...
Page 483: ...Table 1 Cover assembly FC 5095 Expansion I O Tower Analyze hardware problems 471...
Page 614: ...602 Hardware Remove and Replace Part Locations and Listings...
Page 618: ...606 Hardware Remove and Replace Part Locations and Listings...
Page 621: ......
Page 622: ...Printed in USA SY44 5917 02...