Symptom-to-FRU Index (Type 3518)
This index supports the PC Server Enterprise Expansion
Enclosure (Type 3518).
The system management subsystem consists of a main
processor that acts as the controller. The controller
monitors the system temperature, the power supply, the
fan rotation, and the system voltages. If a non-fatal error
is detected, an error code or error message is displayed
on the information panel. Fatal errors are logged to the
system EEPROM and displayed at the next power-on.
Use this Symptom-to-FRU Index to help you decide which
FRUs to have available when servicing the expansion
enclosure.
For information on:
Go to:
Power supply problems
“Power Supplies (Type 3518)”
on page 20
Error Code/Symptom
FRU/Action
E700 AC Failure
(Power lost while the
enclosure was running. The
error is displayed the next
power-on.)
1. Power Cord
2. Power Supply
E701 Power Supply
(Redundant power supply
indicates a bad condition.
Error is non-fatal and can
be cleared by pressing the
front panel Enter button.)
1. Power Supply
E702 5V Failure
(Enclosure 5V input is low
or too high. If too low,
non-fatal error is written to
the information panel. If to
high, enclosure is shutdown
and the error is displayed
the next power-on.)
1. Power Supply
2. System Board (Planar)
703 12V Failure
(Enclosure 12V input is low
or too high. If too low,
non-fatal error is written to
the information panel. If to
high, enclosure is
shutdowns and the error is
displayed the next
power-on.)
1. Power Supply
2. System Board (Planar)
PC Server Type 3518
25