9. Touch the static-protective package that contains the new ServeRAID-MR10is
SAS/SATA adapter to any unpainted surface on the outside of the server; then,
grasp the adapter by the top edge or upper corners of the adapter and remove
it from the package.
10. If the battery pack (battery carrier and battery) did not come installed on the
ServeRAID-MR10is SAS/SATA adapter, install the battery pack.
a. Align the battery carrier pins and the connector for the battery carrier with
the pin holes and connector on the ServeRAID adapter; then, lower the
battery carrier onto the ServeRAID adapter.
b. Press the battery carrier into the connector on the ServeRAID adapter until
it is firmly connected.
c. Secure the battery carrier to the ServeRAID adapter with the screws that
came with the battery pack.
11. Take the signal cable that is attached to the drive backplane and connect it to
the ServeRAID adapter. The following illustration shows the connectors on the
controller to which you connect the signal cable from the drive backplane.
12. Route the signal cables from the drive backplane through the fan cage hole on
the left of fan 1 as shown in the following illustration.
Chapter 2. Installing optional devices
51
Summary of Contents for 4251
Page 1: ...IBM System x3250 M3 Types 4251 4252 and 4261 Installation and User s Guide ...
Page 2: ......
Page 3: ...IBM System x3250 M3 Types 4251 4252 and 4261 Installation and User s Guide ...
Page 7: ...Index 85 Contents v ...
Page 8: ...vi IBM System x3250 M3 Types 4251 4252 and 4261 Installation and User s Guide ...
Page 34: ...18 IBM System x3250 M3 Types 4251 4252 and 4261 Installation and User s Guide ...
Page 100: ...84 IBM System x3250 M3 Types 4251 4252 and 4261 Installation and User s Guide ...
Page 105: ......
Page 106: ... Part Number 81Y6118 Printed in USA 1P P N 81Y6118 ...