Important:
The cooling module bay must not be empty for more than two minutes while the enclosure is
powered up.
Inserting a cooling module
1.
Rotate the cooling module so that the black release latch and handle are on the right side.
2.
Slide the cooling module into its slot until the latch clicks home. The enclosure automatically detects
and uses the new unit.
Replacing a power supply unit (PSU)
The process involves removing the existing module and inserting a new one.
Removing a PSU
Important:
Before removing a PSU, make sure you have a replacement module to insert.
1.
Identify the PSU to be removed by using appropriate fault reporting software.
2.
Ensure the other PSU has the “Power OK” LED lit.
3.
Turn off the PSU to be removed.
4.
Disconnect the AC power cord.
5.
As shown in the following two figures, push the red release latch to the right and hold it (1), then
pull the module out by its handle (2).
Figure 36. Removing a Cooling Module (2)
44
Installation and User Guide - Model 084
Summary of Contents for 5147-084
Page 1: ...IBM ESS expansion Version 5 1 Installation and User Guide Model 084 SC27 4628 01 IBM...
Page 4: ...iv Installation and User Guide Model 084...
Page 6: ...vi Installation and User Guide Model 084...
Page 8: ...viii Installation and User Guide Model 084...
Page 16: ...xvi Installation and User Guide Model 084...
Page 20: ...CAUTION A hot surface nearby L007 4 Installation and User Guide Model 084...
Page 44: ...Figure 20 Anti tamper locks 28 Installation and User Guide Model 084...
Page 68: ...52 Installation and User Guide Model 084...
Page 80: ...64 Installation and User Guide Model 084...
Page 81: ......