• All power cables were removed from the enclosure, as described in “Powering off the 5U92 disk
• The expansion enclosure is removed from the rack, as described in “Removing a 5U92 disk enclosure
• A lift is supporting the weight of the enclosure.
• The top cover, fans, drives, and other heavy FRUs are removed from the enclosure.
About this task
The 5U expansion enclosure contains two fan interface boards (FIBs). The FIBs act as the interface
between the fans and the system drive board. FIB 1 connects fan modules 1 and 2 to the drive board; FIB
2 connects fan modules 3 and 4. If the fault LED on each fan module is lit, it is possible that the FIB that
controls those modules needs to be replaced. You can also issue the
lsenclosurefanmodule
command to display the status of the fans.
If you removed the FIBs from a faulty expansion enclosure, you must reinstall them in the replacement
enclosure. Refer to the procedure described in “Replacing a disk enclosure ” on page 51.
Procedure
1. Assemble the new FIB, cover, and the cover screws (shown in Figure 65 on page 65) in a safe
location.
Figure 65. FIB parts for the chassis
2. Carefully insert the new FIB into the expansion enclosure chassis, as shown in Figure 66 on page
Chapter 3. Maintaining the system hardware 65
Summary of Contents for 5U92
Page 1: ...IBM Cloud Object Storage System Version 3 15 6 J15 Appliance Manual IBM...
Page 10: ...x...
Page 12: ...xii...
Page 24: ...xxiv IBM Cloud Object Storage System Version 3 15 6 J15 Appliance Manual...
Page 32: ...4 IBM Cloud Object Storage System Version 3 15 6 J15 Appliance Manual...
Page 140: ...112 IBM Cloud Object Storage System Version 3 15 6 J15 Appliance Manual...
Page 141: ......