If you have changed the configuration of the system-board tray, you might have to
update the server configuration through the Setup utility (see “Updating the server
configuration” on page 51).
Reinstalling a 3U chassis in an iDataPlex rack
Statement 4:
≥
18 kg (39.7 lb)
≥
32 kg (70.5 lb)
≥
55 kg (121.2 lb)
CAUTION:
Use safe practices when lifting.
To reinstall a 3U chassis in an iDataPlex rack, complete the following steps:
1. Align the 3U chassis with the rails on the iDataPlex rack; then, slide the 3U
chassis into the rack until it is fully seated.
2. Install the M6 screws that secure the chassis to the rack.
3. Install the hard disk drives (see “Installing a hard disk drive” on page 36).
4. Reconnect the cables on the front of the system-board tray.
5. Turn on the system-board tray (see “Turning on the system-board tray” on page
6. Make sure that the power-on LED on the system-board tray operator panel is lit
continuously, indicating that the system-board tray is receiving power and is
turned on.
50
System x iDataPlex dx360 M2: User's Guide
Summary of Contents for 6380
Page 1: ...System x iDataPlex dx360 M2 Types 6313 6380 6385 6386 7321 7323 7831 and 7834 User s Guide...
Page 2: ......
Page 3: ...System x iDataPlex dx360 M2 Types 6313 6380 6385 6386 7321 7323 7831 and 7834 User s Guide...
Page 7: ...Index 77 Contents v...
Page 8: ...vi System x iDataPlex dx360 M2 User s Guide...
Page 14: ...xii System x iDataPlex dx360 M2 User s Guide...
Page 66: ...52 System x iDataPlex dx360 M2 User s Guide...
Page 90: ...76 System x iDataPlex dx360 M2 User s Guide...
Page 94: ...80 System x iDataPlex dx360 M2 User s Guide...
Page 95: ......
Page 96: ...Part Number 90Y5680 Printed in USA 1P P N 90Y5680...