3. To select a controller (channel) from the list of adapters, use the arrow keys and
press Enter.
4. To change the settings of the selected items, follow the instructions on the
screen. If you select
Device Properties
or
Mirroring Properties
, additional
screens are displayed.
When you have finished changing settings, press Esc to exit from the program;
select
Save
to save the settings that you have changed.
Formatting a SCSI hard disk drive
Low-level formatting removes all data from the hard disk. If there is data on the disk
that you want to save, back up the hard disk before you perform this procedure.
Note:
Before you format a SCSI hard disk, make sure that the disk is not part of a
mirrored pair. From the list of adapters, select the controller (channel) for the drive
that you want to format. Select
Mirroring Properties
and make sure that the
mirroring value for the drive is
None
.
To format a drive, complete the following steps:
1. From the list of adapters, select the controller (channel) for the drive that you
want to format.
2. Select
Device Properties
.
3. To highlight the drive that you want to format, use the Up Arrow and Down
Arrow keys. To scroll left and right, use the Left Arrow and Right Arrow keys or
the End key.
4. To start the low-level formatting operation, select
Format
and press Enter.
Creating a mirrored pair of SCSI hard disk drives
To create a mirrored pair of SCSI hard disk drives, complete the following steps:
1. From the list of adapters, select the controller (channel) for the drives that you
want to mirror.
2. Select
Mirroring Properties
.
3. Use the arrow keys to highlight the first drive in the pair; then, press the Minus
key to change the mirroring value to
Primary
.
4. Use the arrow keys to highlight the second drive in the pair; then, press the
Minus key to change the mirroring value to
Secondary
.
5. To establish a third drive that will take over the function of either mirrored drive
in the event of a failure, use the arrow keys to highlight the drive that you want
to use for that purpose; then, press the Minus key to change the mirroring value
to
Hot Spare
.
Configuring a ServeRAID controller
Use the information in this section to configure an optional ServeRAID controller. If
you need to configure an optional LSI RAID controller, see “Using the LSI Logic
Configuration Utility program” on page 63.
Important:
Some cluster solutions require specific code levels or coordinated code
updates. If the device is part of a cluster solution, verify that the latest level of code
is supported for the cluster solution before you update the code.
Chapter 4. Configuring the dx360 M2 server
65
Summary of Contents for 6380
Page 1: ...System x iDataPlex dx360 M2 Types 6313 6380 6385 6386 7321 7323 7831 and 7834 User s Guide...
Page 2: ......
Page 3: ...System x iDataPlex dx360 M2 Types 6313 6380 6385 6386 7321 7323 7831 and 7834 User s Guide...
Page 7: ...Index 77 Contents v...
Page 8: ...vi System x iDataPlex dx360 M2 User s Guide...
Page 14: ...xii System x iDataPlex dx360 M2 User s Guide...
Page 66: ...52 System x iDataPlex dx360 M2 User s Guide...
Page 90: ...76 System x iDataPlex dx360 M2 User s Guide...
Page 94: ...80 System x iDataPlex dx360 M2 User s Guide...
Page 95: ......
Page 96: ...Part Number 90Y5680 Printed in USA 1P P N 90Y5680...