background image

6

“SMART” RS-232 Port

The RS-232 port connects your UPS to any workstation or server. Use with Tripp Lite
software and included cable to monitor and manage network power and automatically
save open files and shut down equipment during a blackout. This port uses RS-232
communications to transmit UPS and power conditions (Pin 7 = Transmit; Pin 8 =
Common; Pin 9 = Receive). Contact Tripp Lite Customer Support for more information
and a list of available SNMP, network management and connectivity products.

Battery Replacement Door

Under normal conditions, the original batteries in your UPS will last several years.
Battery replacement should only be performed by qualified service personnel.  Refer
to “Battery Warnings” in the Safety section on page 2.  When replacing batteries,
qualified service personnel should follow this procedure: 1) turn UPS OFF; 2) remove
the battery door located on the front panel; 3) pull batteries partially out of the case;
4) make a detailed sketch of the batteries and the polarity, color and connection of all

cables; 5) disconnect battery terminals; 6) dispose of used batteries; 7) reconnect replacement batteries
exactly as original batteries were; 8) push batteries back into case and replace cover.*

* You may not receive full runtime until your replacement batteries have fully charged.

Specifications

Storage & Service

Storage

Turn your UPS OFF: first, engage the ON/Standby Switch and release it to place your UPS in the “Standby”
mode; then set the System Enable Switch to “DISABLE”; finally, disconnect the UPS power cord from the
wall outlet.  If you plan on storing your UPS for an extended period of time, recharge the UPS batteries once
every three months.  Follow steps #1 and #3 in the Installation section and allow the UPS to charge from
4 to 6 hours.  If you leave your UPS batteries discharged for an extended period of time, they will suffer
permanent loss of capacity.

Service

If returning your UPS to Tripp Lite, please carefully pack the UPS using the ORIGINAL PACKING MATERIAL
that came with the unit. Enclose a letter describing the symptoms of the problem. If the UPS is within the
2 year warranty period, enclose a copy of your sales receipt.

NP700RM

Output Capacity (VA/Watts):

700/450

Battery Runtime (Half Load/Full Load) Min.:

28/12

Battery Recharge Time:

2-4  hrs.

Suggested Circuit:

15 amp

Approvals:

UL, cUL, FCC Class B

Input Voltage/Frequency (120V/60 Hz);  On Line Input Voltage Range (87 - 140 Volts); Voltage-Regulated Output Voltage Range

(120V +/- 9%); On Battery Output Voltage Range (120V +/- 5%); Output Waveform Line Mode (filtered sinewave); Output Waveform Battery Mode

(PWM sine wave); AC Surge Suppression (exceeds IEEE 587 Cat. A & B standards); AC Noise Attenuation (>40 dB); AC Protection Modes (H to

N, H to G, N to G).

FCC Radio/TV Interference Notice
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates,
uses and can radiate radio frequency energy, and if not installed and used in accordance with the instruction manual, may cause interference
to radio communications.  However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to
try to correct the interference using one or more of the following measures: reorient or relocate the receiving antenna; increase the separation
between the equipment and receiver; connect the equipment into an outlet on a circuit different from that which the receiver is connected; consult
the dealer or an experienced radio/television technician for help.  The user must use shielded cables and connectors with this product. Any
changes or modifications to this product not expressly approved by the party responsible for compliance could void the user's authority to
operate the equipment.

The policy of Tripp Lite is one of continuous improvement.  Specifications are subject to change.

Summary of Contents for 700 RM UPS

Page 1: ...am 5 30pm CST Mon Fri www ReliableUPS com Manufactured for distributed through and sold by Tripp Lite official licensee for this product IBM the IBM logo trademark and the IBM trade dress are owned by...

Page 2: ...Battery Warnings Your UPS does not require routine maintenance Do not open your UPS for any reason There are no user serviceable parts inside Battery replacement must be performed by qualified servic...

Page 3: ...his switch activates the battery charger and microprocessor The XXX light will flash until you engage the ON Standby Switch to activate the ON mode Engage the momentary ON Standby Switch UPS front pan...

Page 4: ...d Let the UPS charge for 12 hours and perform a second self test If the light continues to stay on contact Tripp Lite for service CAUTION Do not unplug your UPS to test its batteries This will remove...

Page 5: ...the green light will turn ON and the more the UPS will click These are both normal automatic operations of your UPS and no action is required on your part This red light will turn ON if your UPS fails...

Page 6: ...pacity Service IfreturningyourUPStoTrippLite pleasecarefullypacktheUPSusingtheORIGINALPACKINGMATERIAL that came with the unit Enclose a letter describing the symptoms of the problem If the UPS is with...

Page 7: ...talaci n R pida p 9 Operaci n B sica p 10 Almacenaje y Servicio p 13 Especificaciones p 13 Seguridad p 8 Warranty Insurance p 6 Fabricado por Tripp Lite bajoconcesi ndelicenciaotorgadaIBM Tripp Lite O...

Page 8: ...er as Este no break no requiere mantenimiento rutinario alguno No abra el no break por ninguna raz n Esta unidad no contiene partes interiores que puedan ser reparadas por el usuario El reemplazo de l...

Page 9: ...esoresdesobretensionestransitoriasaeste no break Encienda el sistema UPS 3 2 1 4 Interruptor System Enable activar sistema Ubicado en el Panel Fronte I ENABLE ACTIVAR O DISABLE DESACTIVAR Coloque el I...

Page 10: ...nativamente del modo ON Encendido y suministrar energ a a los recept culos del sistema UPS al modo Standby Reserva y desactivar los recept culos del sistema UPS Interruptor Mute Test Silenciador Autop...

Page 11: ...ones normales y autom ticas del sistema UPS y no requieren ninguna acci n de su parte Esta luz roja se iluminar si el sistema UPS no pasa la autoprueba y su bater a no est totalmente cargada Permita q...

Page 12: ...les incluidas con este sistema UPS tendr n una vida til de varios a os de duraci n El reemplazo de las bater as solamente debe ser realizado por personal t cnico capacitado Refi rase a la secci n Segu...

Page 13: ...Salida EnBater a sinusoidalmoduladaenanchodepulso Supresi ndeSobretensionesdeCA excedelasnormasIEEE587Categor asAy B Atenuaci ndeRuidosdeCA 40dB ModosdeProtecci ndeCA PositivoaNeutro PositivoaTierra N...

Page 14: ...k R seau Intelligent ANGLAIS p 1 ESPAG OL p 7 Installation Rapide p 16 Op ration de Base p 17 Entreposage Service p 20 Caract ristiques p 20 S ret p 15 Warranty Insurance p 6 ConceptionsousAccorddeLic...

Page 15: ...as des suppresseurs de surtension la prise de votre syst me d UPS Ceci endommagera le syst me d UPS et mettra fin aux garantiesdevotresuppresseur de surtension et de votre syst me d UPS Recommandation...

Page 16: ...exion d appareils lectrom nagers d imprimateslaseroudesuppresseursde surtensionn estpasrecommand e Allumez votre syst me d UPS 3 2 1 4 Positionnez le Commutateur du Syst me Enable sur la position ENAB...

Page 17: ...mentan ment et lib rez le pour permuter entre le mode ON mise sous tension aux r ceptacles de l UPS et le mode Standby mise hors tension aux r ceptacles de l UPS Commutateur de Mute Test Amortissage T...

Page 18: ...ont normales et automatique et il ne faut rien faire Cet indicateur rouge s allumera si votre syst me d onduleur choue un auto test et la batterie n a pas une charge compl te Laissez le syst me d ondu...

Page 19: ...de br lure Observez les pr cautions et utilisez des outils insul s Ne courtez pas et ne cr ez pas un pont aux terminales de la batterie Remplacez la batterie avec une batterie du m me type Plomb et Ac...

Page 20: ...et relachez le afin de placer votre syst me d UPS sur le mode Standby positionnez ensuite le Commutateur du Syst me Enable sur DISABLE d connectez enfin le cordon d alimentation de votre syst me d UP...

Reviews: